AF2ZP0CL - ACE2 - User Manual
Page - 41/85
SUBMENU "ADJUSTMENTS"
1) SET BATTERY TYPE
It selects the nominal battery voltage.
2) ADJUST
BATTERY
Fine adjustment of the battery voltage measured by the controller.
3) THROTTLE 0 ZONE
It establishes a dead band in the lift potentiometer input curve (see also
curve below).
4) THROTTLE X POINT
This parameter, together with the THROTTLE Y POINT, changes the
characteristic of the lift potentiometer input curve : when the potentiometer is
depressed to X point per cent, the corresponding pump speed is Y point per
cent of the Maximum pump speed. The relationship between the lift
potentiometer position and the pump speed is linear between the THROTTLE
0 ZONE and the X point and also between the X point and the maximum
potentiometer position but with two different slopes.
5) THROTTLE Y POINT
This parameter, together with the THROTTLE X POINT, changes the
characteristic of the lift potentiometer input curve (see also paragraph 13.5):
when the potentiometer is de-pressed to X point per cent, the corresponding
pump speed is Y point per cent of the Maximum pump speed. The
relationship between the potentiometer position and the pump speed is linear
between the THROTTLE 0 ZONE and the X point and also between the X
point and the maximum accelerator position but with two different slope.
VACC MIN and VACC MAX are values programmable by the "Program
Vacc" function.
6) BATT.
MIN.
ADJ.
It adjusts the lower level of the battery discharge table. It is used to calibrate
the discharge algorithm with the battery of the application. See chapter 9.5
for more information.
Summary of Contents for ACE2
Page 7: ...AF2ZP0CL ACE2 User Manual Page 7 85 2 3Block diagram...
Page 28: ...Page 28 85 AF2ZP0CL ACE2 User Manual 7 3Connection drawing Traction configuration...
Page 29: ...AF2ZP0CL ACE2 User Manual Page 29 85 7 4Connection drawing Pump configuration...
Page 30: ...Page 30 85 AF2ZP0CL ACE2 User Manual 7 5Connection drawing Combi configuration...
Page 33: ...AF2ZP0CL ACE2 User Manual Page 33 85 8 3 2 Pump configuration...