OPERATION MODES

FUNCTIONALITY BY CONTROL OF EXTA LIFE SYSTEM

TRANSMITTERS 

CAUTION: Two push-buttons of a transmitter are always used in case of SRP-22 roller 

blind controller. For example, P-457/4 remote control (4 push-button) allows for independ-

ent control of two SRP-22 receivers (two roller blinds).

Particular push-buttons of radio EXTA LIFE transmitters can be assigned to different operation 

modes: local and central (see Programming push-buttons of EXTA LIFE radio transmitters).

Local control mode 

•  Local control mode allows to stop a roller blind in any position. It is used to control one roller 

blind. In this mode, pressing shortly one push-button realises the opening function and press-

ing shortly the other push-button realises the closing function. In case a roller blind is in motion, 

pressing any push-button causes the roller blinds stops.

•  Roller blind movement time upwards / downwards is in accordance with time adjusted in the 

controller. The default times are 120 seconds. Longer pressing (>2 sec.) the push-button of a 

transmitter causes the activation of favourite settings. By favourite settings we understand a 

defined % of roller blind closure. In case of local control, it is possible to programme only two 

favourite settings, which are activated independently on current roller blind position. 

Central control mode

Central control mode allows only for a total opening or closure of a single roller blind or a group of 

roller blinds. In this mode, it is not possible to stop a roller blind in a desired position. The central 

mode is used mainly to control a group of roller blinds or to cooperate with sensors. In this mode, 

pressing shortly one push-button realises the opening function and pressing shortly the other 

push-button realises the closing function. In case a roller blind is opened, pressing the closing 

push-button causes the roller blind stops (for about 0,5 sec.) and automatically closes it. The 

same occurs in case of closing a roller blind. Its movement time either upward or downward is in 

accordance with time adjusted in the controller. The default times are 120 seconds. 

FUNCTIONALITY BY CONTROL OF IN1, IN2 EXTERNAL INPUTS

DOUBLE ROLLER BLIND PUSH-BUTTON 

Local control

In this mode, pressing shortly (<0,5 sec.) suitable push-buttons connected to IN1, IN2 inputs, 

activates the following modes: opening, closing or stopping a roller blind. Roller blind movement 

time is in accordance with time adjusted in the controller (default time is 120 sec.). Pressing the 

local control push-button for the first time, causes the roller blind moves in a selected direction, 

however the subsequent push-button pressing stops the roller blind. Longer pressing (>2 sec.) the 

suitable local control push-button causes the activation of favourite settings. By favourite settings 

we understand a defined % of roller blind closure. The settings are activated independently of 

current roller blind position.

 

CAUTION: Favourite settings are common for external outputs and push-buttons of ra-

dio transmitters. If the SRP-22 controller is paired with the EXTA LIFE controller, then 

by means of a mobile application, it is possible to define the roller blind motion by IN1 

and IN2 input.

Summary of Contents for SRP-22

Page 1: ...operate in a local or central control mode Single and double roller blind push buttons can be applied in both cases Due to the two way communication between a receiver and a controller the current rol...

Page 2: ...special measuring equip ment 3 Connect the device cables with the terminals in accordance with the installing diagram 4 Install SRP 22 in a junction box 5 Switch on the power supply from the mains and...

Page 3: ...means of the mobile application 10 A remote software update of a controller is also possible due to the mobile application the EXTA LIFE controller must be connected to the Internet 3 It is recommende...

Page 4: ...a roller blind in a desired position The central mode is used mainly to control a group of roller blinds or to cooperate with sensors In this mode pressing shortly one push button realises the opening...

Page 5: ...blind closure A single push button can activate only one favourite setting programmed as setting 1 Central control In this mode pressing shortly 0 5 sec a roller blind push button the SRP 22 activates...

Page 6: ...perate properly by means of the mobile application The of roller blind closure is calculated on the basis of these times Favourite position positions By means of a mobile application it is possible to...

Page 7: ...means of the EXTA LIFE mobile application DIRECT PROGRAMMING BY MEANS OF PROG PUSH BUTTON To assign radio transmitters directly to a receiver use the receiver s PROG push button ASSIGNING PUSH BUTTON...

Page 8: ...ed 1 Pair the selected SRP 22 receiver with a controller 2 Pair the controller with a transmitter whose buttons you want to assign remotely to a receiver 3 Choose the Assign a receiver option by means...

Page 9: ...ckly to signal times have been assigned correctly PROGRAMMING ROLLER BLIND MOTION TIME In the SRP 22 controller the default closing and opening time of a roller blind is adjusted to 120 seconds During...

Page 10: ...m pletely 2 After a complete roller blind opening press again the Configure closing time push button it causes the roller blind closes 3 Immediately after a complete roller blind closure press again t...

Page 11: ...ly 2 Press the PROG push button shortly 1sec in a receiver STATUS LED switches on blue 3 Wait for about 5 seconds till STATUS LED switches on red 4 Wait another 5 seconds till STATUS LED switches off...

Page 12: ...utton and in 5 sec press it again shortly 3 The STATUS LED flashes orange to signal the deleting is ongoing The LED flashes orange quickly to signal the operation has been completed successfully FAVOU...

Page 13: ...E DELETION OF TRANSMITTERS BY MEANS OF EXTA LIFE APLICATION In case we want to delete remotely push buttons of a transmitter from a receiver it is required that the receiver is paired with the EXTA LI...

Page 14: ...moves up or down By marking fields next to the TEST push button we choose receivers to be paired with the EXTA LIFE controller It is possible to mark more than one receiver 4 Press the PAIR push butto...

Page 15: ...cess of receivers To protect correctly your system the following steps must be carried out 1 If there is no controller in the EXTA LIFE system switch off pairing Broadcast OFF in all receiv ers 2 If t...

Page 16: ...ol IN1 input functionality roller blind closing IN2 input functionality roller blind opening IN1 IN2 inputs are triggered only from the L line The basic functionality requires giving short 0 5 sec imp...

Reviews: