background image

REMOTE TIME PROGRAMMIMG BY MEANS

OF EXTA LIFE APPLICATION

Opening and closing time configuration of a roller blind, which cooperates with the SRP-22 control-

ler is possible by means of a mobile application. To do it, first pair the particular SRP-22 controller 

with the EXTA LIFE system controller. Next, to configure times, choose the “Configure” option from 

the receiver’s menu. Then, from the configuration screen set basic parameters for the particular 

controller. Current closing and opening times, read from a particular controller, are shown in the 

form of “Closing time” and “Opening time” parameters. A user can manually change their values in 

the range from 1 second to 18 hours.

Closing time configuration

To configure the closing time, the following steps are required:

1. Press shortly the “Configure closing time” push-button – it forces the roller blind opens com-

pletely.

2. After a complete roller blind opening, press again the “Configure closing time” push-button – it 

causes the roller blind closes.

3. Immediately after a complete roller blind closure, press again the “Configure closing time” push-

button – to finish time programming procedure of a roller blind.

4. Press the “Save” button to save time in a controller.

 

Opening time configuration

To configure the opening time, the following steps are required:

1. Press shortly the “Configure opening time” push-button – it forces the roller blind closes com-

pletely.

2. After a complete roller blind closure, press again the “Configure opening time” push-button – it 

causes the roller blind opens.

3. Immediately after a complete roller blind opening, press again the “Configure opening time” push-

button – to finish time programming procedure of a roller blind.

4. Press the “Save” button to save time in a controller.

Push-button to configure 

closing time

Currently adjusted closing/opening times 

with a possibility to enter manually values 

from 1 sec. ÷ 10 min.

Push-button to configure 

opening time

Summary of Contents for SRP-22

Page 1: ...operate in a local or central control mode Single and double roller blind push buttons can be applied in both cases Due to the two way communication between a receiver and a controller the current rol...

Page 2: ...special measuring equip ment 3 Connect the device cables with the terminals in accordance with the installing diagram 4 Install SRP 22 in a junction box 5 Switch on the power supply from the mains and...

Page 3: ...means of the mobile application 10 A remote software update of a controller is also possible due to the mobile application the EXTA LIFE controller must be connected to the Internet 3 It is recommende...

Page 4: ...a roller blind in a desired position The central mode is used mainly to control a group of roller blinds or to cooperate with sensors In this mode pressing shortly one push button realises the opening...

Page 5: ...blind closure A single push button can activate only one favourite setting programmed as setting 1 Central control In this mode pressing shortly 0 5 sec a roller blind push button the SRP 22 activates...

Page 6: ...perate properly by means of the mobile application The of roller blind closure is calculated on the basis of these times Favourite position positions By means of a mobile application it is possible to...

Page 7: ...means of the EXTA LIFE mobile application DIRECT PROGRAMMING BY MEANS OF PROG PUSH BUTTON To assign radio transmitters directly to a receiver use the receiver s PROG push button ASSIGNING PUSH BUTTON...

Page 8: ...ed 1 Pair the selected SRP 22 receiver with a controller 2 Pair the controller with a transmitter whose buttons you want to assign remotely to a receiver 3 Choose the Assign a receiver option by means...

Page 9: ...ckly to signal times have been assigned correctly PROGRAMMING ROLLER BLIND MOTION TIME In the SRP 22 controller the default closing and opening time of a roller blind is adjusted to 120 seconds During...

Page 10: ...m pletely 2 After a complete roller blind opening press again the Configure closing time push button it causes the roller blind closes 3 Immediately after a complete roller blind closure press again t...

Page 11: ...ly 2 Press the PROG push button shortly 1sec in a receiver STATUS LED switches on blue 3 Wait for about 5 seconds till STATUS LED switches on red 4 Wait another 5 seconds till STATUS LED switches off...

Page 12: ...utton and in 5 sec press it again shortly 3 The STATUS LED flashes orange to signal the deleting is ongoing The LED flashes orange quickly to signal the operation has been completed successfully FAVOU...

Page 13: ...E DELETION OF TRANSMITTERS BY MEANS OF EXTA LIFE APLICATION In case we want to delete remotely push buttons of a transmitter from a receiver it is required that the receiver is paired with the EXTA LI...

Page 14: ...moves up or down By marking fields next to the TEST push button we choose receivers to be paired with the EXTA LIFE controller It is possible to mark more than one receiver 4 Press the PAIR push butto...

Page 15: ...cess of receivers To protect correctly your system the following steps must be carried out 1 If there is no controller in the EXTA LIFE system switch off pairing Broadcast OFF in all receiv ers 2 If t...

Page 16: ...ol IN1 input functionality roller blind closing IN2 input functionality roller blind opening IN1 IN2 inputs are triggered only from the L line The basic functionality requires giving short 0 5 sec imp...