Video Bitrate
2K – 100M (
2M
)
Textbox for entering video bitrate.
10.8
Values Appearing at the Bottom of All Tabs
Parameter
Options (default in bold italics)
Description
preset
encoder
(any user-defined profiles)
--- new preset ---
The configuration file selected for use.
encoder
: Factory default settings
Can also add more profiles by selecting
--- new
preset ---
.
Save Button
Click to save preset value to the selected
configuration.
Stop All Button
Stop all current encode channels. Encode must
be stopped in order for settings to be altered.
Start All Button
Start all encode channels.
System Status
OK
10.9
ZFinder
Buttons
Description
Refresh
Rescans the network for Z3 Technology products
Edit Device
Allows for manual edits to encoder settings:
Name
:
Name visible in ZFinder and top right corner of user interface (useful
when multiple units are on the same network)
IP Address
Subnet Mask
Gateway
Open Device
Opens the HTTP-based graphical user interface (GUI)
Flash LEDs
Causes status LED on the selected HETM-DCK-21 to flash red approximately 30
times. This is helpful when physically locating one of multiple devices on the
same network.