66
Data Bits
5
6
7
8
Sets the number of data bits sent per serial
message, most serial devices expect 8 data bits.
Parity
None
Odd
Even
Sets serial parity for serial ports. Most devices
expect none.
Stop Bits
1
2
Sets number of stop bits for serial port. Most
devices expect 1.
Function
Camera 1 (VISCA)
Camera 2 (VISCA)
IR camera
Off
User
RS485(PTZ)
FlexIO spare (pins 9+11)
Connect to Serial 1
Connect to Serial 4
Sets the function of the serial port.
The “Connect to Serial X” option will create a bi-
directional cross-connect between this row’s serial
port, and another serial port named “Serial X”.
TCP Port
TCP port used for remote terminal server.
PTZ Configuration
Type
Absolute
Relative
Type of PTZ control expected.
Flip
None
Flip Pan Axis
Flip Tilt Axis
Flip Pan & Tilt
Flips Axis for PT Controls
Position
Most Recent Command
Query Device
Software can be set to use either the position after
the most recent comment or to query the device
each time.
Max Tilt
90 degrees
100 degrees
180 degrees
Sets the maximum tilt of the device