The thermostat can be removed from the Z-Wave network process similar to the inclusion process.
Set your primary controller to EXCLUDE.
Z-Wave Repeater
functionality is enabled for all line powered devices in a Z-Wave network.
When power is first applied to this device it will broadcast a Hail message followed by a Node Informa-
tion frame. This behavior is to maintain backwards compatibility with older controllers that work with
this line of devices.
The Thermostat’s node type is fixed when it is included to the Z-Wave network; if the C-Wire is not
connected and is only battery-powered when including to the network, the Thermostat will remain a
frequent listening routing slave (FLiRS) node until it is removed from the network.
When your thermostat is running on battery power, the Z-Wave radio will turn off to help con-
serve battery life. The Thermostat Z-Wave radio module supports Z-Wave beaming, which
allows other devices in the network to wake up the Z-Wave module and accept commands
and then go back to sleep.
When your thermostat is running on C-Wire power, the Z-Wave radio will stay on and actively
help route messages within the Z-Wave network. The thermostat’s node type is fixed when
it is included to the Z-Wave network; if the C-Wire is present and powered when including
to the network, the thermostat will remain an always- listening node until it is removed from
the network
Security 2
is suppored by this device.
Table 1: Supported Command Classes
Category
Command Class
Security Level
Application
Basic
n/a
Application
Configuration
Authenticated
Application
Multilevel Sensor
Authenticated
Application
Thermostat Fan Mode
Authenticated
Application
Thermostat Fan State
Authenticated
Application
Thermostat Mode
Authenticated
Application
Thermostat Operating State
Authenticated
Application
Thermostat Setpoint
Authenticated
Management
Association
Authenticated
Management
Association Group Info
Authenticated
Management
Battery
Authenticated
Management
Device Reset Locally
Authenticated
Management
Firmware Update Meta Data
Authenticated
Management
Manufacturer Specific
Authenticated
Management
Version
Authenticated
Management
Z-Wave Plus Info
non-secure
Network
Powerlevel
Authenticated
Transport
Security S2
non-secure
Transport
Supervision
non-secure
Transport
Transport Service
non-secure
Lifeline
is supported by this device.
The device only supports Association Group 1, which can hold up to 2 nodes.
If at least one node is added to association group one (1), the thermostat will send the following reports
when the respective state has changed:
• Basic Report