CT200-G1 User Guide
Wire Reference Table
Warning:
If there are both B and O wires (Trane pump products) DO NOT CONNECT B to B terminal
Instead, connect B to C terminal. If not a Trane product, tape off B.
Table 1: General Reference
Label
RTCOA
HVAC Function
R,V,VR
RH and RC
Single power for HEAT and COOL
RH,4
RH
Power for HEAT (RH not connected to RC)
RC
RC
Power for COOL (RH not connected to RC)
W
W
1st stage HEAT or 1st stage auxiliary heat
W2
W2
2nd stage HEAT or 2nd stage auxiliary heat
W3
W3
3rd stage HEAT or 2nd stage of 2 stage auxiliary heat
Y
Y
COOL control or 1st stage compression for heat pump
Y2
Y2
2nd stage COOL or compression for a heat pump
G,F
G
FAN control
C,X
C
24VAC power (to power thermostat)
H
H
External Humidifier
DH
DH
External De-Humidifier
EX
EX
External fresh air baffle
B
B
Heat pump changeover (cool to heat, powered in heat)
O
O
Heat pump changeover (heat to cool, powered in cool)
B and O
[WARNING]
E
n/a
Emergency heat (do not connect, tape off)
L
n/a
System monitor (do not connect, tape off)
T
n/a
Outdoor sensor (do not connect, tape off)
Table 2: Manufacturer Specific Wiring
Manufacturer
Label
RTCOA
HVAC Function
Lenox Heat Pump
V,VR,R
RH
Power for HEAT
M,Y
Y
COOL control
Y,W,W2
W2
2nd stage HEAT
F,G
G
Fan control
R,O
O
Changeover (powered in cool)
X,X2,C
C
24VAC power (to thermostat)
Trane (American Standard)
B
C
24VAC power (to thermostat)
X2
n/a
Emergency heat (do not connect)
12
Chapter 1. Installation Guide
Summary of Contents for CT200-G1
Page 1: ...CT200 G1 User Guide Radio Thermostat Jul 29 2019 ...
Page 2: ......
Page 4: ...ii ...
Page 18: ...CT200 G1 User Guide 14 Chapter 1 Installation Guide ...