Page 1: ...Installation Manual Model RT510RF ...

Page 2: ...0 Operations 11 Setting the time 11 Programming the RT510RF 12 Functions 14 Review the Setpoint temperature 14 Temporary Override 14 Permanent Override 15 Boost Function 15 a Boost Function in Normal Mode 16 b Boost Function in Permanent Override Mode 16 c Boost Function in Temporary Override Mode 17 d Boost Function in Frost Holiday Mode 18 Frost Function 18 Holiday Function 19 Other Functions 20...

Page 3: ...s www saluslegal com Safety Information Use in accordance with the EU and national regulations For indoor use only Keep your device completely dry ThisproductmustbeinstalledbyacompetentpersonandinaccordancewithalltheEUandnationalregulations Always isolate the AC Mains supply before installing or working on any components that require 230 VAC 50Hz supply Box content 2x screws and plugs 1x Thermosta...

Page 4: ...Any adjustments above these settings will waste energy and cost you more money If your heating system is a boiler with radiators there will usually be only one programmable room thermostat to control the whole house But you can have different temperatures in individual rooms by installing thermostatic radiator valves TRVs on individual radiators If you don t have TRVs you should choose a temperatu...

Page 5: ...itch Terminal Common Switch Terminal Mains Live 230VAC Mains Neutral 1 RXRT510 Receiver 5 2 days or 24h programming flexibility Built in start up programming for quick installation Volt free contacts Frost protection Large easy to read LCD with blue backlight Burner on symbol User friendly Stylish casing Holiday Mode Boost Function NO COM L N L N Electrical diagram Installation Features RT510RF In...

Page 6: ...s shown below The following tables show the default settings of the RT510 thermostat after Power on or after Reset button is pressed Function Status after Reset Operation Mode Normal mode Room Temperature 22 0 C to be renewed within 5 seconds C indicator On Clock 12 00 AM PM indicator AM Program Default factory setting Setpoint Temperature Default factory setting Program Number indicator 1 SET ind...

Page 7: ...tion Hr SELECT SELECT SET SET Press for 3 seconds in order to activate Holiday Mode Press once to activate deactivate Boost function Press once to enter exit Permanent Override function Increase button Decrease button Select the clock or programme settings Press to confirm your settings Press the buttons for 3 seconds to enter Installer Mode Press the buttons for 3 seconds to enter Clock Settings ...

Page 8: ...to set up a communication between them Pairing procedure Note Turn the receiver off and on again ON OFF ON The red LED will start flashing ON AUTO OFF MANUAL ON AUTO OFF MANUAL ON AUTO OFF MANUAL 1 Current day of the program 2 Current time 3 Temperature unit 4 AM PM 5 Frost Mode ON 6 Holiday Mode ON 7 Temporary Permanent Override 8 Heating Mode ON 9 Low battery 10 Boost Mode ON 11 Current temperat...

Page 9: ...n until the pairing process will automatically end or you can follow the steps below ON AUTO OFF MANUAL 2 4 TEST PAIRING SELECT Hr SET TEST PAIRING SELECT Hr SET 3Sec 1 2 TEST PAIRING SELECT Hr SET TEST PAIRING SELECT Hr SET 3Sec TEST PAIRING Hr SELECT SET TEST PAIRING Hr SELECT SET 1Sec Testing procedure 1 2 1 3 RT510RF Installation Manual 09 ...

Page 10: ...ue d01 Temperature display increments 0 1 or 0 5 C Select temperature display increments 0 5 C d02 Temperature offset 3 0 C Calibrate your thermostat temperature 0 0 C d03 Frost setpoint 5 0 17 0 C Set the Frost Point temperature 5 0 C RESET Hr SELECT SET RESET Hr SELECT SET 3Sec 3Sec 3Sec RESET Hr SELECT SET Press and hold all three buttons together for 3 sec Press Set in order to changed the set...

Page 11: ...uttons together for 3 sec Press Up or Down to select the hour format 1 2 RESET Hr SELECT SET 3Sec 3Sec RESET Hr SELECT SET Press Select and after that Up or Down to set the minutes Continue with the same steps for setting the Day Press Set to save your options and return to the main Screen 5 6 Press Up or Down to set the hour 4 Press Select to confirm 3 RESET Hr SELECT SET RESET Hr SELECT SET RESE...

Page 12: ...nnel Weekends 6 sets of time channel Total 12 settings week 24h Programme 24h 6 sets of time channel Total 42 settings week Press Up or Down to selectWeekday Weekend or the Day for which you want to create the program Press Set to change your programmes RESET Hr SELECT SET RESET Hr SELECT SET 2 1 Press Up Down to set the hour Press Select to confirm your option RESET Hr SELECT SET 4 RESET Hr SELEC...

Page 13: ...h to 24h in order to have the individual programme active After that please follow the same instructions as for the 5 2 days programme Press Select to confirm your option RESET Hr SELECT SET 5 Press Up Down to set the minutes RESET Hr SELECT SET RESET Hr SELECT SET Press Select to confirm your option RESET Hr SELECT SET Press Up Down to set the temperature 6 7 8 RT510RF Installation Manual 13 ...

Page 14: ... the setpoint desired temperature follow the steps below Actual room temperature Setpoint desired temperature Press Up Down to review the setpoint temperature Press Up Down to set the temperature Note To exit the temporary override procedure you can wait for 3 seconds until the set temperature stops flashing or you can press on the SET button once 1 1 2 2 RESET Hr SELECT SET RESET Hr SELECT SET RE...

Page 15: ...you can override temporary override or permanently override the thermostat by setting the period of time and also by changing the Setpoint temperature See below the explanations for the Boost Mode settings that are available for each of the modes set on the thermostat Please follow the one that suits you needs Note To exit the temporary override procedure you can wait for 3 seconds until the set t...

Page 16: ...s Set to save your options and to return to Main screen 4 SET Note RT510RF will work in Boost Mode for up to 9 hours set on the desired temperature After the Boost time is over the thermostat will return to Normal Mode and will follow the schedule created by you b Boost Function in Permanent Override Mode RESET Hr SELECT SET Each press on means an extra hour added on the Boost function The maximum...

Page 17: ...mporary Override Mode RESET Hr SELECT SET Each press on means an extra hour added on the Boost function The maximum is 9 hours Hr RESET Hr SELECT SET 1 RESET Hr SELECT SET 1 Press Up or Down to set the temperature After the temperature is set press Set to save your options and to return to main screen RESET Hr SELECT SET 4 SET Note RT510RF will work in Boost Mode for up to 9 hours set on the desir...

Page 18: ...SELECT SET Frost function allows you to turn the Frost protection ON or OFF The frost setpoint temperature is preset at 5 C You can change the frost setpoint temperature by modifying the Installer Mode parameters d03 If the room temperature is lower than the Frost setpoint then the thermostat will automatically change to Frost mode ON Follow the steps below for setting up the Frost Mode Press the ...

Page 19: ...Hr SELECT SET RESET Hr SELECT SET SET 1dy Press Up Down to set the Holiday period Max 31 days Holiday function will turn off the relay blocking your thermostat from sending any call for heat If room temperature is lower than the frost setpoint then Frost Mode will be activated Follow the steps below in order to set the Holiday Mode 3 4 5 6 1 2 RESET Hr SELECT SET 4 RESET Hr SELECT SET 4 3 sec RT51...

Page 20: ...ould replace the batteries as soon as possible to prevent any possible operating problems When you want to change the batteries your device will use the internal memory to backup your settings You have 30 sec to change the batteries before losing your settings Sleep Mode By pressing both the UP and DOWN keys together the RT510RF will enter SLEEP mode In this mode all the RT510RF functions will be ...

Page 21: ...10TX Temperature Scale 5to35ºC Device Parameters Seepage9 Operating Temperature 0to40ºC Storage Temperature 20to60ºC Reset Function The Reset Button is provided as a way to restore the programmable thermostat to its default factory settings Pressing this button will delete any previously entered settings This should only be done by your installer RESET Hr SELECT SET Press the Reset button once You...

Page 22: ...cification for a period of two years from the date of installation SALUS Controls sole liability for breach of this warranty will be at its option to repair or replace the defective product Customer Name Customer Address Post Code Tel No Email Company Name Tel No Email Installation Date Installer Name Installer Signature 22 RT510RF Installation Manual ...

Page 23: ... tech salus tech com www salus controls com SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserves the right to change specification design and materials of products listed in this brochure without prior notice For the latest PFD Instruction Manual go to www salus manuals com Issue Date April 2017 V001 ...