YZ Systems, Inc. • 3101 Pollok Drive • Conroe, Texas • USA • 77303 • P: 936.788.5593 • F: 936.788.5720
Page 50
NJEX 8300 ver .092001 ATEX Rev.
SSSSS
ECTION
ECTION
ECTION
ECTION
ECTION
8:
8:
8:
8:
8: W
W
W
W
W
ORKING
ORKING
ORKING
ORKING
ORKING
WITH
WITH
WITH
WITH
WITH
THE
THE
THE
THE
THE
N-300 S
N-300 S
N-300 S
N-300 S
N-300 S
Y
YY
Y
YSTEM
STEM
STEM
STEM
STEM
D
D
D
D
D
ISPLA
ISPLA
ISPLA
ISPLA
ISPLAY
YY
Y
YSSSSS
Or
To View Real-Time Displays,
Continued
Expansion Tank
This display illustrates the expansion tank pressure,
figure 139
.
Odorant Inlet
Displays the pressure of the bulk odorant storage tank
via the pressure transmitter located at the fill rate control
valve,
figure 140
.
Battery Voltage
The battery voltage is shown in this display,
figure 141
.
•
Battery Alarm,
a low battery is when the voltage is
less then 11.5 VDC,
figure 141a
.
Flow Input
This display,
figure 142,
illustrates the flow rate as a
percentage of the maximum gas flow. The following
represent the alarms that are associated with this area
of the N-300G controller.
Flow Input Alarms
•
Loss of Signal,
figure 143,
the flow signal is less than
.5 VDC, for the analog input only.
•
Over Flow,
figure 144,
the flow input has exceeded
125% of the maximum gas flow.
Flow Input Indicators, non-alarm
•
Low Flow,
figure 145,
the flow input has fallen below
the low flow shut off set point
refer to Section 5,
Programming for Proportional-to-Flow page 26.
•
Over Flow
,
figure 146,
the flow input has exceeded
110% of the maximum gas flow, but is still less than
125% of maximum gas flow.
•
No Flow,
figure 147,
is presently indicated by the flow
signal.
•
Low Flo Shtoff,
figure 148,
the flow signal indicates a
flow rate less than programmed for odorization.
Or
pmp bat vmtr sig tnk
Battery 14.3 VDC
pmp bat vmtr sig tnk
Odorant Inlet
35.3 psig
pmp bat vmtr sig tnk
Odorant Inlet
2.434 bar
pmp bat vmtr sig tnk
Expansion Tank
25.2 psig
pmp bat vmtr sig tnk
Expansion Tank
1.739 bar
Figure 139
Figure 140
pmp bat vmtr SIG tnk
Flow Input 0.0%
Pulse (PPM)
Loss of Signal
pmp bat vmtr sig tnk
Battery 14.3 VDC
Low Battery
pmp bat vmtr sig tnk
Flow Input 63.1%
L i n e a r
pmp bat vmtr sig tnk
Flow Input 0.0%
Pulse (PPM)
pmp bat vmtr SIG tnk
Flow Input 125.1%
Pulse (PPM)
OverFlow >125%
pmp bat vmtr sig tnk
PropFlow 0.06
*Stop *Dsp *Set
Low Flow Shtoff
pmp bat vmtr sig tnk
Flow Input 110.1%
Pulse (PPM)
OverFlow >110%
pmp bat vmtr sig tnk
Flow Input 0.0%
Pulse (PPM)
No Flow
pmp bat vmtr sig tnk
Flow Input 2.0%
Pulse (PPM)
Low Flo Shtoff
Figure 141
Figure 141a
Figure 142
Figure 143
Figure 144
Figure 145
Figure 146
Figure 147
Figure 148