ATEX System Connections
Required field connections to place the 7300L into
operation are as follows:
1. Connect your I.S. Power Supply to the yellow
cable connection coming from the bottom of the
N-300 controller, and exiting the rear of your
system enclosure,
refer to the Wiring Control
Document on page 116 in Appendix D
.
.
2. Connect the flow signal device to the termina-
tion block located in the system control enclo-
sure,
figure 8
,
refer to the Wiring Control
Document on page 116 in Appendix D
.
2a. If used, connect the optional Inhibit Input signal
to the termination block located in the system
control enclosure,
figure 8
,
refer to the Wiring
Control Document on page 116 in Appendix D
.
2b. If used, connect the RS-485 communication
wiring as required to the termination block
located in the system control enclosure,
figure
8
,
refer to the Wiring Control Document on page
116 in Appendix D
.
I.S. Power Supply
Connection