pmp bat vmtr sig tnk
Calibration Set
*
Clk
*Inputs *Esc
pmp bat vmtr sig tnk
Set Date and Time
00:00 06-01-Thu-2000
pmp bat vmtr sig tnk
Calibration
*
Flow
*Pres *Esc
pmp bat vmtr sig tnk
Calibrate Pressure
*
XTank
*Odor *Esc
pmp bat vmtr sig tnk
Zero Adjustment
*
Read
1.0 VDC
*Esc
pmp bat vmtr sig tnk
Zero Adjustment
Accept/ERROR x.x V *Esc
pmp bat vmtr sig tnk
Flow Input Type
*
Ang
*Pulse *Esc
pmp bat vmtr sig tnk
Analog Input
*
Lin
*NLin *Esc
pmp bat vmtr sig tnk
Span Adjustment
xxx Pulses/(Min)(Sec) *Esc
pmp bat vmtr sig tnk
Pulse Input
*
PPS
*PPM *Esc
pmp bat vmtr sig tnk
Linear/Non-Linear Input
*
Zero
*Span *Esc
pmp bat vmtr sig tnk
Zero Adjustment
Read 1.0 VDC *Esc
pmp bat vmtr sig tnk
Span Adjustment
*
Read
5.0 VDC *Esc
pmp bat vmtr sig tnk
Span Adjustment
Accept/ERROR x.x V *Esc
pmp bat vmtr sig tnk
Zero Adjustment
Accept/ERROR x.x V *Esc
pmp bat vmtr sig tnk
Alarm Out Status
*Set *Test *Esc
pmp bat vmtr sig tnk
Pump Alarm
Disabled/Enabled
pmp bat vmtr sig tnk
Alarm Switch Test
OFF/Alarm Relay Closed/
(ON/Alarm Relay Open)
pmp bat vmtr sig tnk
Switch/Simulation
*Sw *Sim *Esc
pmp bat vmtr sig tnk
Battery Alarm
Disabled/Enabled
pmp bat vmtr sig tnk
Verometer Alarm
Disabled/Enabled
pmp bat vmtr sig tnk
Signal Alarm
Disabled/Enabled
pmp bat vmtr sig tnk
Tank Alarm
Disabled/Enabled
pmp bat vmtr sig tnk
Pump Alarm
Simulate
pmp bat vmtr sig tnk
Battery Alarm
Simulate
pmp bat vmtr sig tnk
Verometer Alarm
Simulate
pmp bat vmtr sig tnk
Signal Alarm
Simulate
pmp bat vmtr sig tnk
Tank Alarm
Simulate
Over Pump
PMP bat vmtr sig tnk
Pump Alarm
Simulate
Under Pump
PMP bat vmtr sig tnk
Pump Alarm
Simulate
Pump Failure
PMP bat vmtr sig tnk
Pump Alarm
Simulate
1
12
12
Low Battery
pmp BAT vmtr sig tnk
Battery Alarm
Simulate
12
Vmtr-Cable
pmp bat VMTR sig tnk
Verometer Alarm
Simulate
1
1
No-Fill
pmp bat VMTR sig tnk
Verometer Alarm
Simulate
1
1
Slow Fill
pmp bat VMTR sig tnk
Verometer Alarm
Simulate
12
Flvalv-Fail
pmp bat VMTR sig tnk
Verometer Alarm
Simulate
1
1
Overfill
pmp bat VMTR sig tnk
Verometer Alarm
Simulate
1
1
Fillrate
pmp bat VMTR sig tnk
Verometer Alarm
Simulate
1
OdorInlet-Cabl
pmp bat VMTR sig tnk
Verometer Alarm
Simulate
1
1
OdorInlet-Lo
pmp bat VMTR sig tnk
Verometer Alarm
Simulate
1
1
XTank-Cable
pmp bat VMTR sig tnk
Verometer Alarm
Simulate
1
1
XTank-Hi
pmp bat VMTR sig tnk
Verometer Alarm
Simulate
1
1
OdodInlet-Hi
pmp bat VMTR sig tnk
Verometer Alarm
Simulate
1
1
Leakage
pmp bat VMTR sig tnk
Verometer Alarm
Simulate
1
XTank-Lo
pmp bat VMTR sig tnk
Verometer Alarm
Simulate
12
12
OverFlow>125%
pmp bat vmtr SIG tnk
Signal Alarm
Simulate
12
12
12
12
12
12
12
12
OverFlow>110%
pmp bat vmtr sig tnk
Verometer Alarm
Simulate
Low-Flo Shtoff
pmp bat vmtr sig tnk
Verometer Alarm
Simulate
No Flow
pmp bat vmtr sig tnk
Verometer Alarm
Simulate
Loss of Signal
pmp bat vmtr SIG tnk
Signal Alarm
Simulate
12
12
12
Odor Tank Hi
pmp bat vmtr sig TNK
Tank Alarm
Simulate
Odor Tank Low
pmp bat vmtr sig TNK
Tank Alarm
Simulate
N-300 Controller Display
Diagram,
Figure 212
Serial Number
Model Type
8300G
Verometer Calibrate
xx.xxx calicrate cc
pmp bat vmtr sig tnk
PropFlow (Time) Idle
*Strt *Dsp *Set
pmp bat vmtr sig tnk
Strokes Signaled
*Reset xxxxxxxx
pmp bat vmtr sig tnk
Reset Strokes?
*No *Yes
pmp bat vmtr sig tnk
Odorant Injected
*Reset xx.xxxxlbs(kg)
Pre-Config
Yes No
pmp bat vmtr sig tnk
Reset lbs(kg) Injected?
*No *Yes
N-300G Ver x.xx
-- NJEX --
PMP
bat vmtr sig tnk
xx.xxx cc/stroke*
Pump Displacement
Alarm
1
1
over pump
under pump
pump failure
pmp
bat
VMTR
sig tnk
Meter Level xxx%
*Fill
Fill Verometer?
*No *Yes
Alarm
1
1
Vmtr-Cable
No Fill
Slow Fill
Fill Valve
OdorInlet-
Cable
OdorInlet Lo
OdorInlet Hi
XTank-Cable
XTank Low
XTank H
Non-Alarms
ver Fill
fill rate
Leakage
pmp
bat vmtr sig tnk
Expansion Tank
xx.x psi (Bar)
pmp
bat vmtr sig tnk
OdorInlet
Inlet
xx.x psig (Bar)
Linear
Non Linear
Pulse PPS/PPM
Alarm
Loss of Signal
(Analog input
only)
Over Flow
>125%
Non Alarm
No Flow
Low Flo
Shtoff
Over flow
<125%
Alarm
1
1
low battery
pmp
BAT
vmtr sig
tnk
Battery xx.x VDC
Alarm
1
1
pmp
bat vmtr
SIG
tnk
Flow Input xx.x%
Alarm
1
1
pmp
bat vmtr sig
T N K
Low Level
High Level
Odorant Temp xx C
12:00 04-12-Wed-
2000
pmp bat vmtr sig tnk
Meter Level xxx%
pmp bat vmtr sig tnk
Proportional To ?
*Flow *Time
*Esc
pmp bat vmtr sig tnk
Start Pump?
*Yes
*No *Esc
pmp bat vmtr sig tnk
Prop Flow/Time x:xx:xx
*Stop
*Dsp *Set
pmp bat vmtr sig tnk
Time/Stroke Calculated
Exceeds minimum
pmp bat vmtr sig tnk
Stop Pump
*
No
*
Yes
pmp bat vmtr sig tnk
Set Selection
*
Par
*Cal *Esc
pmp bat vmtr sig tnk
Set Parameters
*
Flow
*Time *Esc
pmp bat vmtr sig tnk
Injection Rate
x.xxx lbs/MMCF(mg/m3)
pmp bat vmtr sig tnk
Proportional To Flow
* Set *Alarm * Esc
pmp bat vmtr sig tnk
Pump Displacement
x.xxx cc/stroke
pmp bat vmtr sig tnk
Odorant Density
x.xxx lbs/gallon (g/cc)
pmp bat vmtr sig tnk
Proportional To Time
* Set *Alarm * Esc
Proportional To Time
pmp bat vmtr sig tnk
Set Time/Stroke
xx.xx Minutes
pmp bat vmtr sig tnk
Max Gas Flow
xx.xxx MMCF/(m3/sec)
pmp bat vmtr sig tnk
Low Flow Shut Off
xx.x% max gas flow
pmp bat vmtr sig tnk
Flow (no signal)
xx.xx% max gas flow
pmp bat vmtr sig tnk
Max Time/Stroke
xxx minutes/stroke
pmp bat vmtr sig tnk
Odorant Output
x.xx lb/pulse (kg/pulse)
pmp bat vmtr sig tnk
Odorant Tank
xx=Low (%) xx=High
pmp bat vmtr sig tnk
Expansion Tank
xx=Low (psi) xx=High
pmp bat vmtr sig tnk
Odorant Inlet
xx=Low (psi)(Bar) xx=High
xxxxx
pmp bat vmtr sig tnk
Alarm to Relay Delay
xxx minutes
pmp bat vmtr sig tnk
Alarm to Callout Delay
xxx minutes
pmp bat vmtr sig tnk
MODBUS Address
xxx = Device Address
pmp bat vmtr sig tnk
MODBUS Parameters
9600,N,RTU,Comm=..