YZ Systems, Inc. • 3101 Pollok Drive • Conroe, Texas • USA • 77303 • P: 936.788.5593 • F: 936.788.5720
Page 33
NJEX 8300 ver.092001 ATEX Rev.
SSSSS
ECTION
ECTION
ECTION
ECTION
ECTION
66666::::: P
P
P
P
P
R
RR
R
ROGRAMMING
OGRAMMING
OGRAMMING
OGRAMMING
OGRAMMING
FOR
FOR
FOR
FOR
FOR
P
P
P
P
P
R
RR
R
ROPOR
OPOR
OPOR
OPOR
OPORTION
TION
TION
TION
TIONAL
AL
AL
AL
AL
-----
TTTTTO
O
O
O
O
-----TTTTT
IME
IME
IME
IME
IME
O
O
O
O
O
PERA
PERA
PERA
PERA
PERATION
TION
TION
TION
TION
Or
*designates optional key function
pmp bat vmtr sig tnk
Set Parameters
*Flow *Time *Esc
pmp bat vmtr sig tnk
Proportional to Time
*Set *Alarm *Esc
pmp bat vmtr sig tnk
Odorant Density
6.80 lbs/Gal
pmp bat vmtr sig tnk
Odorant Density
0.815 g/cc
pmp bat vmtr sig tnk
Set Selection
*Par *Cal *Esc
pmp bat vmtr sig tnk
PropFlow Idle
*Strt *Dsp *Set
pmp bat vmtr sig tnk
Pump Displacement
6.000 cc/Stroke
Select
Enter
Select
Enter
Select
Enter
Figure 57
Figure 58
Figure 59
Figure 60
Figure 61
Figure 62
Figure 63
Setting Operator Input Parameters
Choose Set from the main menu,
figure 57.
Choose Par from the set selection menu,
figure 58.
Choose Time from the set parameters menu,
figure 59.
Choose Set from the proportional-to-time menu,
figure 60.
Pump displacement in cc/stroke
To set the pump displacement,
figure 61,
press and
release the Select key. The value entry will begin to
flash when chosen. Use the Up Arrow key to increase
the value and the Down Arrow key to decrease the
value. When a new value has been chosen, press the
Enter key to store the new value into memory. The
entered value will stop flashing when it has been loaded
into memory. Press the Down Arrow key to advance to
the next parameter.
Odorant density in lbs/gallon
(g/cc.) @ 60ºF
To set the odorant density,
figure 62,
press and
release the Select key. The value entry will begin to
flash when selected. Use the Up Arrow key to increase
the value and the Down Arrow key to decrease the
value. When a new value has been chosen, press the
Enter key to store the new value into memory. The
entered value will stop flashing when it has been loaded
into memory. Press the Down Arrow key to advance to
the next parameter.
Time interval between strokes of the pump in
xx.xx minutes/stroke:
1. 0.00 minutes = proportional-to-time disabled.
2. 0.02 to 99.99 minutes = proportional-to-time
enabled.
To set the time/strokes,
figure 63,
press and release
the Select key. The value entry will begin to flash when
chosen. Use the Up Arrow key to increase the value
and the Down Arrow key to decrease the value.
pmp bat vmtr sig tnk
Set Time Per Stroke
0.50 minutes