Johnson Controls Unitary Products

Accessories  

Part Number

Description

1RC0470

Roof Curb, 8" Height

1RC0471

Roof Curb, 14" Height

1RC0472

Roof Curb, Transition (7.5 T through 12.5 T)

1BD0408

Burglar Bars, Downflow

2TP04520925

Electric Heat 9kW 230V

2TP04521825

Electric Heat 18kW 230V

2TP04522425

Electric Heat 24kW 230V

2TP04523625

Electric Heat 36kW 230V

2TP04525425

Electric Heat 54kW 230V

2TP04520946

Electric Heat 9kW 460V

2TP04521846

Electric Heat 18kW 460V

2TP04522446

Electric Heat 24kW 460V

2TP04523646

Electric Heat 36kW 460V

2TP04525446

Electric Heat 54kW 460V

2TP04520958

Electric Heat 9kW 575V

2TP04521858

Electric Heat 18kW 575V

2TP04522458

Electric Heat 24kW 575V

2TP04523658

Electric Heat 36kW 575V

2TP04525458

Electric Heat 54kW 575V

2TP04540925

Electric Heat 9kW 230V, 42" Tall Cabinet

2TP04541825

Electric Heat 18kW 230V, 42" Tall Cabinet

2TP04542425

Electric Heat 24kW 230V, 42" Tall Cabinet

2TP04543625

Electric Heat 36kW 230V, 42" Tall Cabinet

2TP04540946

Electric Heat 9kW 460V, 42" Tall Cabinet

2TP04541846

Electric Heat 18kW 460V, 42" Tall Cabinet

2TP04542446

Electric Heat 24kW 460V, 42" Tall Cabinet

2TP04543646

Electric Heat 36kW 460V, 42" Tall Cabinet

2TP04540958

Electric Heat 9kW 575V, 42" Tall Cabinet

2TP04541858

Electric Heat 18kW 575V, 42" Tall Cabinet

2TP04542458

Electric Heat 24kW 575V, 42" Tall Cabinet

2TP04543658

Electric Heat 36kW 575V, 42" Tall Cabinet

1FA0413

Manual Outside Air Damper 0-35%, Downflow (Incl. Hood, Damper & Filters, No Barometric Relief)

1FA0414

Manual Outside Air Damper 0-100%, Downflow (Incl. Hood, Damper & Filters, No Barometric Relief)

2MD04702724

Motorized Damper, Downflow (Incl. Hood, Damper & Filter, no Barometric Relief)

2MD04703324

Motorized Damper, Horizontal (Incl. Hood, Damper & Filter, no Barometric Relief)

2EE04705924

Economizer, Downflow (Incl. Barometric Relief & All Hoods)

2EE04706024

Economizer, Horizontal (Incl. Dampers & Hoods, no Barometric Relief)

2EE04705724

Economizer, Slab, Downflow (Incl. Dampers only no Hoods or Barometric Relief), 50” Tall Cabinet

2EE04705824

"Downflow Economizer, Slab type for ERV (no Barometric Relief or FA hood)", 42" Tall Cabinet

2PE04703225

Power Exhaust, Downflow, 230V (For Units with Economizer only)

2PE04703246

Power Exhaust, Downflow, 460V(For Units with Economizer only)

2PE04703258

Power Exhaust, Downflow, 580V (For Units with Economizer only)

2EC04700924

Dual Enthalpy Control (Use with Single Enthalpy Economizer)

1EH0407

Hood Kit, Downflow Economizer (Included with all Downflow Economizers)

1RD0411

Barometric Relief Kit, Ductmount for Horizontal Application (Incl. Damper & Hood)

1EH0408

Barometric Relief Kit, Ductmount for Horizontal Application w/Power Exhaust (Incl. Damper & Hood)

1EH0409

Barometric Relief / Hood Kit, for Field Installed Slab Econ. w/o ERV (Incl. Barometric Relief & FA Hood)

2AQ04700424

CO2 Detector Unit Mount

2AQ04700324

CO2 Detector Space Mount

2SD04700824

Smoke Detector for Supply (All Gen 5 units with 2" & 4" Filters)

2SD04700924

Smoke Detector for Return (All Gen 5 units with 2" & 4" Filters)

2SD04701024

Smoke Detector for Supply and Return (All Gen 5 units with 2" & 4" Filters)

2MK04700624

Low Limit / Compressor Lockout Kit

1CG0419

Coil Guard (Electric / Electric & HP models), 8-1/2 and 10 Ton

1CG0424

Coil Guard (Electric / Electric and HP models), 12-1/2 Ton

1CG0427

Coil Guard (Electric / Electric & HP Models), 6-1/2 and 7-1/2 Ton

1HG0411

Hail Guard Kit

1HG0415

Hail Guard Kit, 42" Tall Cabinet

1FL0402

Permanent Filter Kit

1FL0423

Permanent Filter Kit, 42" Tall Cabinet

2DF0401

Dirty Filter Switch

1FF0414

2” only Metal Filter Frame Kit, 50” Tall Cabinet

1FF0415

2” only Metal Filter Frame Kit, 42" Tall Cabinet

Summary of Contents for Predator XP Series

Page 1: ...s are self contained and assembled on rigid full perimeter base rails allowing for 3 way forklift access and overhead rigging Every unit is completely charged wired piped and tested at the factory to...

Page 2: ...3 4 NPT Female Connection Belt drive blower motor Condenser section Filter drier solid core Filter access 2 or 4 filter options Disconnect location optional disconnect switch Compressor 2 Access High...

Page 3: ...ions 2 3 4 R Options 3 4 S Option 5 T Options 1 5 U Options 1 3 5 V Options 1 4 5 W Options 1 3 4 5 X Options 3 5 Y Options 4 5 Z Options 3 4 5 1 Disconnect 2 Non Pwr d Conv Outlet 3 Smoke Detector S...

Page 4: ...rocating compressors Scroll compressors do not require crankcase heaters Phase Monitors are standard on units with scroll compressors This accessory monitors the incoming power to the unit and protect...

Page 5: ...or air As the outdoor air intake dampers open the return air dampers close The changeover from mechanical refrigeration to economizer operation is regulated by the standard single enthalpy input There...

Page 6: ...rrosion ElectroFin E coat Evaporator Coils The evaporator coils are coated with an epoxy polymer coating to protect against corrosion Control Options BAS Building Automation System Controls Simplicity...

Page 7: ...unit with a down flow economizer Power exhaust plugs into the connector in the unit bulkhead You must purchase 1EH0408 barometric relief when applying to a horizontal flow application Manual Outdoor A...

Page 8: ...Motorized Damper Horizontal Incl Hood Damper Filter no Barometric Relief 2EE04705924 Economizer Downflow Incl Barometric Relief All Hoods 2EE04706024 Economizer Horizontal Incl Dampers Hoods no Barom...

Page 9: ...nd be accessible through hinged access door Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without rem...

Page 10: ...ailable by either or ELECTRONIC ENTHALPY AUTOMATIC ECONOMIZER Outdoor and return air dampers that are interlocked and positioned by a fully modulating spring return damper actuator The maximum leakage...

Page 11: ...t available SMOKE DETECTOR A smoke detector can be factory mounted and wired in the supply and or return air compartments OTHER PRE ENGINEERED ACCESSORIES AVAILABLE ROOF CURB 14 and 8 high full perime...

Page 12: ...7 3 35 7 9 3 35 8 6 3 30 13 2 3 0 17 F capacity rating Mbh 43 0 51 0 53 0 58 0 90 0 System power KW COP 5 7 2 20 6 4 2 25 6 9 2 25 7 8 2 20 13 5 2 2 HSPF Btu Watts hr DIMENSIONS inches Length 89 89 89...

Page 13: ...1725 Frame size 56 56 56 56 56 56 56 56 56 184T FILTERS Quantity Size 4 24 x 20 x 2 1 2 4 24 x 20 x 2 1 2 4 24 x 20 x 2 1 2 4 24 x 20 x 2 1 2 4 24 x 20 x 2 1 2 4 24 x 20 x 2 3 4 24 x 20 x 4 3 4 24 x 2...

Page 14: ...121 3 4 9 90 6 76 7 62 9 49 1 111 6 5 5 88 1 74 1 60 1 46 1 67 111 3 4 9 111 3 93 3 79 5 65 6 51 8 101 6 5 5 101 6 89 9 75 9 61 9 47 9 62 99 9 4 8 99 9 99 9 97 3 83 5 69 6 55 8 92 3 5 4 92 3 92 3 91...

Page 15: ...6 67 3 8 6 67 3 64 1 53 0 41 8 30 7 62 68 8 7 8 68 8 68 8 66 5 55 1 43 7 32 3 61 6 8 6 61 6 61 6 61 1 49 9 38 8 27 6 57 70 6 7 7 70 6 70 6 67 2 55 8 44 4 33 0 65 0 8 5 65 0 65 0 61 6 50 4 39 3 28 1 2...

Page 16: ...64 0 50 0 113 1 6 5 88 6 74 7 60 8 46 9 67 112 3 5 7 112 3 97 9 83 9 69 9 55 9 103 5 6 5 103 5 94 5 80 6 66 7 52 8 62 106 2 5 6 106 2 106 2 106 2 92 2 78 2 64 2 96 4 6 4 96 4 96 4 96 4 82 5 68 6 54 7...

Page 17: ...9 68 7 10 0 68 7 68 7 58 2 47 1 36 0 62 72 5 9 0 72 5 72 5 73 8 62 5 51 2 39 9 65 9 9 9 65 9 65 9 65 9 57 6 46 6 35 5 57 72 0 9 0 72 0 72 0 74 4 63 1 51 8 40 5 65 2 9 9 65 2 65 2 65 2 57 1 46 0 34 9...

Page 18: ...8 74 9 58 1 128 6 7 1 106 2 89 0 71 8 54 5 67 127 2 6 2 127 2 113 8 96 4 79 5 62 7 117 8 7 0 117 8 111 1 93 9 76 7 59 4 62 115 7 6 1 115 7 115 7 115 7 98 9 82 1 65 2 108 6 7 0 108 6 108 6 108 6 91 3 7...

Page 19: ...1 43 7 79 8 10 9 79 8 79 8 71 5 55 8 40 2 62 81 1 9 8 81 1 81 1 91 3 75 9 60 6 45 2 73 0 10 9 73 0 73 0 73 0 73 0 57 4 41 7 57 84 4 9 9 84 4 84 4 83 1 67 7 52 3 37 0 78 0 10 9 78 0 78 0 76 8 61 1 45 5...

Page 20: ...5 67 133 5 7 1 133 5 123 4 105 7 90 1 74 5 125 5 8 1 125 5 120 4 103 5 86 6 69 8 62 124 4 7 0 124 4 124 4 124 4 108 8 93 2 77 6 117 0 8 0 117 0 117 0 117 0 100 2 83 3 66 4 57 126 7 7 0 126 7 126 7 12...

Page 21: ...0 65 2 48 4 92 3 12 7 92 3 92 3 79 0 62 0 44 9 62 96 1 11 3 96 1 96 1 96 1 79 3 62 5 45 7 86 9 12 5 86 9 86 9 86 9 70 8 53 7 36 7 57 101 9 11 4 101 9 101 9 93 8 77 0 60 2 43 4 93 6 12 7 93 6 93 6 85...

Page 22: ...9 3 190 9 169 3 147 0 124 7 102 4 179 7 10 3 179 7 165 0 142 5 119 9 97 3 62 167 4 9 2 167 4 167 4 167 4 145 1 122 8 100 5 160 9 10 2 160 9 160 9 160 9 138 3 115 8 93 2 57 174 9 9 3 174 9 174 9 174 9...

Page 23: ...7 128 2 15 3 128 2 124 0 105 0 86 1 67 1 62 138 7 13 7 138 7 138 7 127 5 108 5 89 5 70 5 132 0 15 0 132 0 132 0 119 0 100 1 81 1 62 2 57 135 4 13 7 135 4 135 4 126 8 107 8 88 8 69 8 128 2 15 1 128 2 1...

Page 24: ...1 6 3 6 5 6 7 6 9 7 1 7 4 7 6 80 MBH 13 0 24 9 36 7 48 6 60 4 72 3 84 2 96 0 KW 6 9 7 1 7 3 7 5 7 7 7 9 8 1 8 4 3000 55 MBH 20 1 32 0 43 8 55 7 67 6 79 4 91 3 103 2 KW 4 4 4 6 4 9 5 1 5 3 5 5 5 7 5 9...

Page 25: ...H 26 6 46 1 65 7 85 2 104 8 124 4 143 9 163 5 kW 8 44 8 82 9 21 9 60 9 99 10 38 10 76 11 15 70 MBH 22 5 42 0 61 6 81 2 100 7 120 3 139 8 159 4 kW 10 24 10 63 11 02 11 41 11 80 12 18 12 57 12 96 80 MBH...

Page 26: ...1072 1 87 1124 2 04 2400 631 0 16 682 0 41 736 0 66 793 0 90 852 1 14 911 1 36 970 1 58 1028 1 78 1084 1 97 1136 2 13 2600 642 0 27 692 0 52 747 0 76 804 1 01 862 1 24 922 1 47 981 1 69 1039 1 89 1094...

Page 27: ...ressure IWG1 1 Blower performance includes 2 filters See STATIC RESISTANCE table for additional applications 2 See RPM SELECTION table to determine desired motor sheave setting and to determine the ma...

Page 28: ...113 2 02 1153 2 24 2400 689 0 42 743 0 69 800 0 93 859 1 16 919 1 37 978 1 57 1035 1 77 1088 1 97 1135 2 18 1176 2 40 2600 712 0 60 766 0 87 823 1 11 882 1 34 942 1 55 1002 1 75 1058 1 95 1111 2 15 11...

Page 29: ...P RPM BHP RPM BHP RPM BHP RPM BHP 3 HP Field Supplied Drive Standard 3 HP Drive Hi Static 5 HP Drive 3200 757 1 20 811 1 36 864 1 50 915 1 64 964 1 77 1012 1 89 1059 2 02 1104 2 14 1149 2 26 1192 2 38...

Page 30: ...4 0 14 0 07 0 08 0 09 0 10 0 13 2500 0 11 0 16 0 08 0 09 0 10 0 11 0 14 2700 0 18 0 17 0 09 0 10 0 12 0 13 0 16 2900 0 25 0 19 0 10 0 11 0 13 0 14 0 18 3100 0 31 0 20 0 12 0 13 0 15 0 16 0 20 3300 0 3...

Page 31: ...1 95 BHP exceeds the maximum continuous BHP rating of the 1 5 HP motor The 2 HP motor is required 6 1268 RPM is within the range of the 2 HP drives 7 Using the 2 HP motor and drive 5 turns open will...

Page 32: ...0 676 0 651 Electric Heat Minimum Supply Air Size Tons Model Voltage Minimum Supply Air CFM Heater kW 9 18 24 36 54 078 6 5 XP 208 230 3 60 1950 1950 1950 1950 460 3 60 1950 1950 1950 1950 600 3 60 19...

Page 33: ...1 3 4 2 2 2 8 5 3800 2PE04703258 575 1 60 3 4 1050 1 2 9 1 5 1 9 4 3800 Electric Heat Multipliers Voltage kW Capacity Multipliers1 1 Electric heaters are rated at nominal voltage Use this table to det...

Page 34: ...e with AHRI 270 standard Octave Band Centerline Frequency Hz 125 250 500 1000 2000 4000 8000 078 6 5 XP 83 88 0 82 5 81 5 78 0 73 0 69 0 62 0 090 7 5 XP 83 89 5 83 5 82 0 78 0 72 5 68 0 60 5 102 8 5 X...

Page 35: ...49 6 50 60 E09 6 8 1 18 9 67 7 73 2 70 80 E18 13 5 2 37 5 90 9 96 4 100 100 E24 18 2 50 0 106 6 112 1 110 125 E36 25 5 2 70 8 132 6 138 1 150 150 230 15 6 83 1 21 4 1 5 6 0 5 5 0 0 None 44 1 49 6 50 6...

Page 36: ...3 5 2 37 5 114 1 119 6 125 125 E24 18 2 50 0 129 8 135 3 150 150 E36 25 5 2 70 8 155 8 161 3 175 175 E54 40 6 2 112 7 155 8 161 4 175 175 230 22 4 149 0 35 0 1 5 10 9 5 5 0 0 None 67 3 72 8 80 90 E18...

Page 37: ...0 E09 6 8 1 18 9 71 3 76 8 80 80 E18 13 5 2 37 5 94 5 100 0 100 100 E24 18 2 50 0 110 2 115 7 125 125 E36 25 5 2 70 8 136 2 141 7 150 150 230 15 6 83 1 21 4 1 5 9 6 5 5 0 0 None 47 7 53 2 60 60 E09 9...

Page 38: ...13 5 2 37 5 119 3 124 8 125 125 E24 18 2 50 0 135 0 140 5 150 150 E36 25 5 2 70 8 161 0 166 5 175 175 E54 40 6 2 112 7 161 0 167 9 175 175 230 22 4 149 0 35 0 1 5 16 1 5 5 0 0 None 72 5 78 0 90 100 E1...

Page 39: ...E09 6 8 1 18 9 77 7 83 2 80 90 E18 13 5 2 37 5 100 9 106 4 110 110 E24 18 2 50 0 116 6 122 1 125 125 E36 25 5 2 70 8 142 6 148 1 150 150 230 15 6 83 1 21 4 1 5 6 0 5 5 10 0 None 54 1 59 6 60 70 E09 9...

Page 40: ...8 13 5 2 37 5 124 1 129 6 125 150 E24 18 2 50 0 139 8 145 3 150 150 E36 25 5 2 70 8 165 8 171 3 175 175 E54 40 6 2 112 7 167 0 173 9 175 175 230 22 4 149 0 35 0 1 5 10 9 5 5 10 0 None 77 3 82 8 90 100...

Page 41: ...E09 6 8 1 18 9 81 3 86 8 90 90 E18 13 5 2 37 5 104 5 110 0 110 110 E24 18 2 50 0 120 2 125 7 125 150 E36 25 5 2 70 8 146 2 151 7 150 175 230 15 6 83 1 21 4 1 5 9 6 5 5 10 0 None 57 7 63 2 70 70 E09 9...

Page 42: ...13 5 2 37 5 129 3 134 8 150 150 E24 18 2 50 0 145 0 150 5 150 175 E36 25 5 2 70 8 171 0 176 5 175 200 E54 40 6 2 112 7 173 5 180 4 175 200 230 22 4 149 0 35 0 1 5 16 1 5 5 10 0 None 82 5 88 0 100 110...

Page 43: ...528195 YTG I 0513 Johnson Controls Unitary Products 43 Typical Wiring Diagrams XP078 150 Typical Wiring Diagrams Typical XP078 120 Heat Pump with without Electric Heat Wiring Diagram...

Page 44: ...528195 YTG I 0513 44 Johnson Controls Unitary Products Typical XP150 Heat Pump with without Electric Heat Wiring Diagram...

Page 45: ...1085 1080 38 25 262 195 266 357 184 150 124 169 204 250 090 7 5 XP 1095 1090 38 23 243 181 284 381 171 139 115 181 217 267 102 8 5 XP 1142 1137 38 25 5 282 210 276 370 197 161 133 175 211 259 120 10...

Page 46: ...528195 YTG I 0513 46 Johnson Controls Unitary Products XP078 150 Unit Dimensions XP078 120 XP150 See detail A for drain location See detail A for drain location...

Page 47: ...0 3 16 24 3 16 17 3 16 6 3 16 120 50 3 4 89 30 3 16 24 3 16 17 3 16 6 3 16 150 50 3 4 119 1 2 30 3 16 24 3 16 17 3 16 6 3 16 5 3 8 3 4 FPT XP078 150 Unit Clearances Direction Distance in Direction Dis...

Page 48: ...it Electrical Entry XP078 120 Unit Side Duct Openings Disconnect Swith Cover Power Entry 2 1 2 Control Entry 7 8 Power Entry 2 1 2 Convenience Outlet Cover Convenience Outlet Power Entry 7 8 FRONT Dot...

Page 49: ...eft Duct Opening Side Duct Dimensions Unit Model Number Dimension in A B C D 078 28 1 4 18 1 16 28 1 4 18 1 4 090 28 1 4 18 1 16 28 1 4 18 1 4 102 28 1 4 18 1 16 28 1 4 18 1 4 120 28 1 4 18 1 16 28 1...

Page 50: ...ons XP078 150 Roof Curb XP078 150 Transition Roof Curb 8 or 14 50 1 2 30 20 20 80 5 8 6 2 TYP INSULATED DECK UNDER COMPRESSOR SECTION INSULATED DECK UNDER CONDENSER SECTION FRONT RIGHT SUPPLY RETURN 7...

Page 51: ...2 UNIT BASE WOOD NAILER 8 MIN ABOVE FINISHED ROOF CURB FRAME INSULATION UNIT BASE RAILS COUNTERFLASHING CAN T STRIP INSULATION AND ROOFING MATERIAL ROOF DECK AND SUPPORT STRUCTURE 14 3 56 3 75 XP078 1...

Page 52: ...n 42 Slab Economizer 42 tall cabinet 2EE047058242 50 Slab Economizer 50 tall cabinet 2EE047057242 1 Barometric relief must be ordered separately and installed in duct work 2 Barometric relief or fresh...

Page 53: ...ust 1EH0408 Barometric Relief Hood 1EH0408 Barometric Relief Damper 2PE047032XX Power Exhaust 2EE04706024 Fresh Air Hood 2EE04706024 Fresh Air Damper 2EE04706024 Return Air Damper Field Installed Duct...

Page 54: ...s reserved Supersedes 528195 YTG H 0213 Johnson Controls Unitary Products 5005 York Drive Norman OK 73069 Slab Economizer End Return W Power Exhaust 2EE04705X24 Slab Economizer 1EH0409 Barometric Reli...

Reviews: