![background image](http://html2.mh-extra.com/html/york/predator-xp-series/predator-xp-series_technical-manual_4151567015.webp)
528195-YTG-I-0513
Johnson Controls Unitary Products
15
115°F
125°F
1625
77
86.5
7.8
35.6
29.9
22.2
-
-
-
80.1
8.7
30.4
26.7
19.0
-
-
-
72
77.9
7.8
48.0
40.3
32.6
24.9
-
-
71.7
8.6
44.8
37.1
29.4
21.7
-
-
67
69.4
7.8
60.5
50.7
43.0
35.3
27.6
-
63.3
8.6
58.3
47.5
39.8
32.1
24.4
-
62
63.7
7.8
63.7
62.9
50.7
43.0
35.3
27.6
58.0
8.6
58.0
58.0
45.8
38.1
30.4
22.7
1950
77
88.8
7.8
42.4
33.5
24.6
-
-
-
81.8
8.7
38.8
30.0
21.1
-
-
-
72 80.0
7.8
53.8
44.9
36.0
27.1
-
-
73.2
8.6
50.4
41.5
32.6
23.8
-
-
67 71.2
7.8
65.3
56.4
47.4
38.5
29.6
-
64.6
8.6
61.9
53.0
44.2
35.3
26.5
-
62 65.4
7.8
65.4
64.9
55.9
47.0
38.1
29.2
59.2
8.6
59.2
59.2
50.9
42.0
33.2
24.3
57 67.1
7.7
67.1
65.5
56.5
47.6
38.7
29.8
62.4
8.5
62.4
60.2
51.3
42.5
33.6
24.7
2275
77 91.1
7.8
49.3
37.0
26.9
-
-
-
83.5
8.6
47.3
33.3
23.2
-
-
-
72 82.1
7.8
59.7
49.5
39.4
29.2
-
-
74.7
8.6
55.9
45.9
35.9
25.9
-
-
67 73.1
7.8
70.1
62.0
51.9
41.7
31.6
-
65.9
8.6
65.5
58.6
48.6
38.6
28.6
-
62 67.1
7.8
67.1
66.8
61.2
51.0
40.9
30.7
60.4
8.6
60.4
60.4
56.0
46.0
36.0
26.0
57 68.9
7.7
68.9
68.1
61.9
51.7
41.5
31.4
63.7
8.5
63.7
62.6
56.5
46.4
36.4
26.4
2600
77 93.4
7.8
56.1
40.5
29.2
-
-
-
85.2
8.6
55.7
36.5
25.4
-
-
-
72 84.2
7.8
65.5
54.1
42.8
31.4
-
-
76.2
8.6
61.5
50.3
39.2
28.0
-
-
67 74.9
7.8
74.9
67.7
56.3
45.0
33.6
-
67.3
8.6
67.3
64.1
53.0
41.8
30.7
-
62 68.8
7.8
68.8
68.8
66.5
55.1
43.7
32.3
61.6
8.6
61.6
61.6
61.1
49.9
38.8
27.6
57 70.6
7.7
70.6
70.6
67.2
55.8
44.4
33.0
65.0
8.5
65.0
65.0
61.6
50.4
39.3
28.1
2925
72 84.9
7.8
71.9
59.0
46.1
33.2
-
-
76.8
8.6
68.0
55.2
42.4
29.5
-
-
67 75.6
7.8
75.6
72.0
60.7
47.8
35.0
-
67.8
8.6
67.8
67.6
57.3
44.4
31.6
-
62 69.4
7.8
69.4
69.4
68.2
55.3
42.4
29.5
62.1
8.6
62.1
62.1
61.8
49.0
36.2
23.3
57 71.2
7.7
71.2
71.2
69.5
56.6
43.7
30.8
65.5
8.5
65.5
65.5
63.8
51.0
38.1
25.3
3250
72 85.6
7.8
78.2
63.8
49.4
35.0
-
-
77.4
8.6
74.5
60.0
45.5
31.0
-
-
67 76.2
7.8
76.2
76.2
65.1
50.7
36.3
-
68.3
8.6
68.3
68.3
61.5
47.0
32.5
-
62 69.9
7.8
69.9
69.9
69.9
55.5
41.1
26.7
62.6
8.6
62.6
62.6
62.6
48.1
33.6
19.1
57 71.8
7.7
71.8
71.8
71.8
57.4
43.0
28.6
66.0
8.5
66.0
66.0
66.0
51.5
37.0
22.5
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
XP078 (6.5 Ton) (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65