Johnson Controls Unitary Products

5

Units are tested for refrigerant charge and pressure, unit 
amperage, and 100% functionality. For the long term – All 
Predator

®

 units are painted with a long lasting, powder 

paint that stands up over the life of the unit. The paint 
used has been proven by a 1000 hour salt spray test.

Flexible Placement

 – All models and configurations 

share the same cabinet/footprint and thus the same roof 
curb. You have the flexibility to set one curb and choose 
the correct tonnage size and heating option after the 
internal loads have been determined.

To further simplify planning and installation, Predator

®

 XP 

cabinets are designed to fit your roof. With the optional 
roof curb, the unit ductwork is designed to fit around 24” 
on-center joists or between 48” on-center joists.

The drain pan can be rotated to drain to either the front or 
the rear of the unit. Additionally, the drain pan can be 
fitted to drain through the roof curb. As it is sometimes 
difficult to have a level installation, the drain pan features 
a generous slope to ensure proper drainage.

Full Perimeter Base Rails

 – The permanently attached 

base rails provide a solid foundation for the entire unit and 
protect the unit during shipment. The rails offer forklift 
access from 3 sides, and rigging holes are available so that 
an overhead crane can be used to place the units on a roof.

Easy Installation

 – Electric utility knockouts are supplied in 

the unit underside as well as the side of the unit. A clearly 
identified location is provided to mount a field supplied 
electrical disconnect switch. Utility connections can be 
made quickly and with a minimum amount of field labor.

All units are shipped with 2” throw-away filters installed.

Wide Range of Indoor Airflows

 – All indoor fan motors 

are belt-drive type providing maximum flexibility to handle 
most airflow requirements. For high static applications, 
factory installed alternate indoor fan motors are available. 
With the optional indoor fan motor, all units can supply 
nominal airflow at a minimum of 1.5” ESP.

Warranty 

- All models include a 1-year limited warranty 

on the complete unit. Compressors and electric heater 
elements each carry a 5-year warranty.

Factory Installed Options

YORK

®

 offers several equipment options factory installed, for 

the Predator

®

line.

Optional Factory Installed Economizers

 - Predator units 

offer a variety of optional factory installed economizers 
with low leak dampers. The outdoor air enthalpy sensor 
enables economizer operation if the outdoor enthalpy is 
less than the setpoint of the economizer logic module. See 
economizer options section to determine the correct 
economizer for your application.

Downflow Economizer 

(With barometric relief) 

The economizer is provided with a single enthalpy input. 
The economizer is 2% low leakage type, and is shipped 
installed and wired. The installer needs only to 
assemble and mount the outdoor air hood (Provided). 
The economizer has spring return, fully modulating 
damper actuators and is capable of introducing up to 
100% outdoor air. As the outdoor air intake dampers 
open, the return air dampers close. The changeover 
from mechanical refrigeration to economizer operation is 

regulated by the standard single enthalpy input. There is 
an optional input dual dry bulb available. To meet 
regulated air standards, the economizer control accepts 
an optional CO

2

 

input for

 

demand ventilation. With 

single enthalpy input, the economizer control monitors 
outdoor air. The dual enthalpy kit provides a second 
input used to monitor the return air. With a dual input kit 
installed, the economizer control compares the values of 
the two enthalpy or temperature inputs and positions the 
dampers to provide the maximum efficiency possible.

Horizontal Economizer 

(Without barometric relief) 

All features of the downflow economizer exist except you 
must order the duct mount barometric relief separately. 

You must order a 1EH0408 if you are installing a 
power exhaust. You can order a 1RD0411 Barometric 
Relief for horizontal flow economizers only.

BAS Ready Economizer -(With barometric relief) 

The economizer is provided with an actuator that 
requires a 0-10V DC input from an external source (i.e., 
field installed building automation system controller). 
Power exhaust options are available. The economizer is 
2% low leakage type with spring return and fully 
modulating dampers capable of introducing up to 100% 
outside air. Also include 2” pleated filters.

Slab Economizer for Energy Recovery Ventilators

(With barometric relief and Fresh Air Hood) 

- The 

economizer is provided with a single enthalpy input. The 
economizer is 2% low leakage type, and is shipped 
installed and wired. The economizer has spring return, 
fully modulating damper actuators and is capable of 
introducing up to 100% outdoor air. As the outdoor air 
intake dampers open, the return air dampers close. The 
changeover from mechanical refrigeration to 
economizer operation is regulated by the standard 
single enthalpy input. There is an optional input dual dry 
bulb available. To meet regulated air standards, the 
economizer control accepts an optional CO

2

 

input for

 

demand ventilation.With single enthalpy input, the 
economizer control monitors outdoor air. The dual 
enthalpy kit provides a second input used to monitor the 
return air. With a dual input kit installed, the economizer 
control compares the values of the two enthalpy or 
temperature inputs and positions the dampers to 
provide the maximum efficiency possible.

Power Exhaust (Downflow only)

 - This accessory 

installs in the unit with a down flow economizer. 

Motorized Outdoor Air Damper 

- The motorized outdoor 

air damper includes a slide-in/plug-in damper assembly 
with an outdoor air hood and filters. The outdoor air 
dampers open to the preset position when the indoor fan 
motor is energized. The damper has a range of 0% to 
100% outdoor air entry. Factory installed option or field 
installed accessory.

Alternate Indoor Blower Motor 

- For applications with 

high static restrictions, units are offered with optional 
indoor motors that provide higher static output and/or 
higher airflow, depending upon the installer’s needs.

Stainless Steel Drain Pan - 

An optional rust-proof 

stainless steel drain pan is available to provide years of 
trouble-free operation in corrosive environments.

Summary of Contents for Predator XP Series

Page 1: ...s are self contained and assembled on rigid full perimeter base rails allowing for 3 way forklift access and overhead rigging Every unit is completely charged wired piped and tested at the factory to...

Page 2: ...3 4 NPT Female Connection Belt drive blower motor Condenser section Filter drier solid core Filter access 2 or 4 filter options Disconnect location optional disconnect switch Compressor 2 Access High...

Page 3: ...ions 2 3 4 R Options 3 4 S Option 5 T Options 1 5 U Options 1 3 5 V Options 1 4 5 W Options 1 3 4 5 X Options 3 5 Y Options 4 5 Z Options 3 4 5 1 Disconnect 2 Non Pwr d Conv Outlet 3 Smoke Detector S...

Page 4: ...rocating compressors Scroll compressors do not require crankcase heaters Phase Monitors are standard on units with scroll compressors This accessory monitors the incoming power to the unit and protect...

Page 5: ...or air As the outdoor air intake dampers open the return air dampers close The changeover from mechanical refrigeration to economizer operation is regulated by the standard single enthalpy input There...

Page 6: ...rrosion ElectroFin E coat Evaporator Coils The evaporator coils are coated with an epoxy polymer coating to protect against corrosion Control Options BAS Building Automation System Controls Simplicity...

Page 7: ...unit with a down flow economizer Power exhaust plugs into the connector in the unit bulkhead You must purchase 1EH0408 barometric relief when applying to a horizontal flow application Manual Outdoor A...

Page 8: ...Motorized Damper Horizontal Incl Hood Damper Filter no Barometric Relief 2EE04705924 Economizer Downflow Incl Barometric Relief All Hoods 2EE04706024 Economizer Horizontal Incl Dampers Hoods no Barom...

Page 9: ...nd be accessible through hinged access door Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without rem...

Page 10: ...ailable by either or ELECTRONIC ENTHALPY AUTOMATIC ECONOMIZER Outdoor and return air dampers that are interlocked and positioned by a fully modulating spring return damper actuator The maximum leakage...

Page 11: ...t available SMOKE DETECTOR A smoke detector can be factory mounted and wired in the supply and or return air compartments OTHER PRE ENGINEERED ACCESSORIES AVAILABLE ROOF CURB 14 and 8 high full perime...

Page 12: ...7 3 35 7 9 3 35 8 6 3 30 13 2 3 0 17 F capacity rating Mbh 43 0 51 0 53 0 58 0 90 0 System power KW COP 5 7 2 20 6 4 2 25 6 9 2 25 7 8 2 20 13 5 2 2 HSPF Btu Watts hr DIMENSIONS inches Length 89 89 89...

Page 13: ...1725 Frame size 56 56 56 56 56 56 56 56 56 184T FILTERS Quantity Size 4 24 x 20 x 2 1 2 4 24 x 20 x 2 1 2 4 24 x 20 x 2 1 2 4 24 x 20 x 2 1 2 4 24 x 20 x 2 1 2 4 24 x 20 x 2 3 4 24 x 20 x 4 3 4 24 x 2...

Page 14: ...121 3 4 9 90 6 76 7 62 9 49 1 111 6 5 5 88 1 74 1 60 1 46 1 67 111 3 4 9 111 3 93 3 79 5 65 6 51 8 101 6 5 5 101 6 89 9 75 9 61 9 47 9 62 99 9 4 8 99 9 99 9 97 3 83 5 69 6 55 8 92 3 5 4 92 3 92 3 91...

Page 15: ...6 67 3 8 6 67 3 64 1 53 0 41 8 30 7 62 68 8 7 8 68 8 68 8 66 5 55 1 43 7 32 3 61 6 8 6 61 6 61 6 61 1 49 9 38 8 27 6 57 70 6 7 7 70 6 70 6 67 2 55 8 44 4 33 0 65 0 8 5 65 0 65 0 61 6 50 4 39 3 28 1 2...

Page 16: ...64 0 50 0 113 1 6 5 88 6 74 7 60 8 46 9 67 112 3 5 7 112 3 97 9 83 9 69 9 55 9 103 5 6 5 103 5 94 5 80 6 66 7 52 8 62 106 2 5 6 106 2 106 2 106 2 92 2 78 2 64 2 96 4 6 4 96 4 96 4 96 4 82 5 68 6 54 7...

Page 17: ...9 68 7 10 0 68 7 68 7 58 2 47 1 36 0 62 72 5 9 0 72 5 72 5 73 8 62 5 51 2 39 9 65 9 9 9 65 9 65 9 65 9 57 6 46 6 35 5 57 72 0 9 0 72 0 72 0 74 4 63 1 51 8 40 5 65 2 9 9 65 2 65 2 65 2 57 1 46 0 34 9...

Page 18: ...8 74 9 58 1 128 6 7 1 106 2 89 0 71 8 54 5 67 127 2 6 2 127 2 113 8 96 4 79 5 62 7 117 8 7 0 117 8 111 1 93 9 76 7 59 4 62 115 7 6 1 115 7 115 7 115 7 98 9 82 1 65 2 108 6 7 0 108 6 108 6 108 6 91 3 7...

Page 19: ...1 43 7 79 8 10 9 79 8 79 8 71 5 55 8 40 2 62 81 1 9 8 81 1 81 1 91 3 75 9 60 6 45 2 73 0 10 9 73 0 73 0 73 0 73 0 57 4 41 7 57 84 4 9 9 84 4 84 4 83 1 67 7 52 3 37 0 78 0 10 9 78 0 78 0 76 8 61 1 45 5...

Page 20: ...5 67 133 5 7 1 133 5 123 4 105 7 90 1 74 5 125 5 8 1 125 5 120 4 103 5 86 6 69 8 62 124 4 7 0 124 4 124 4 124 4 108 8 93 2 77 6 117 0 8 0 117 0 117 0 117 0 100 2 83 3 66 4 57 126 7 7 0 126 7 126 7 12...

Page 21: ...0 65 2 48 4 92 3 12 7 92 3 92 3 79 0 62 0 44 9 62 96 1 11 3 96 1 96 1 96 1 79 3 62 5 45 7 86 9 12 5 86 9 86 9 86 9 70 8 53 7 36 7 57 101 9 11 4 101 9 101 9 93 8 77 0 60 2 43 4 93 6 12 7 93 6 93 6 85...

Page 22: ...9 3 190 9 169 3 147 0 124 7 102 4 179 7 10 3 179 7 165 0 142 5 119 9 97 3 62 167 4 9 2 167 4 167 4 167 4 145 1 122 8 100 5 160 9 10 2 160 9 160 9 160 9 138 3 115 8 93 2 57 174 9 9 3 174 9 174 9 174 9...

Page 23: ...7 128 2 15 3 128 2 124 0 105 0 86 1 67 1 62 138 7 13 7 138 7 138 7 127 5 108 5 89 5 70 5 132 0 15 0 132 0 132 0 119 0 100 1 81 1 62 2 57 135 4 13 7 135 4 135 4 126 8 107 8 88 8 69 8 128 2 15 1 128 2 1...

Page 24: ...1 6 3 6 5 6 7 6 9 7 1 7 4 7 6 80 MBH 13 0 24 9 36 7 48 6 60 4 72 3 84 2 96 0 KW 6 9 7 1 7 3 7 5 7 7 7 9 8 1 8 4 3000 55 MBH 20 1 32 0 43 8 55 7 67 6 79 4 91 3 103 2 KW 4 4 4 6 4 9 5 1 5 3 5 5 5 7 5 9...

Page 25: ...H 26 6 46 1 65 7 85 2 104 8 124 4 143 9 163 5 kW 8 44 8 82 9 21 9 60 9 99 10 38 10 76 11 15 70 MBH 22 5 42 0 61 6 81 2 100 7 120 3 139 8 159 4 kW 10 24 10 63 11 02 11 41 11 80 12 18 12 57 12 96 80 MBH...

Page 26: ...1072 1 87 1124 2 04 2400 631 0 16 682 0 41 736 0 66 793 0 90 852 1 14 911 1 36 970 1 58 1028 1 78 1084 1 97 1136 2 13 2600 642 0 27 692 0 52 747 0 76 804 1 01 862 1 24 922 1 47 981 1 69 1039 1 89 1094...

Page 27: ...ressure IWG1 1 Blower performance includes 2 filters See STATIC RESISTANCE table for additional applications 2 See RPM SELECTION table to determine desired motor sheave setting and to determine the ma...

Page 28: ...113 2 02 1153 2 24 2400 689 0 42 743 0 69 800 0 93 859 1 16 919 1 37 978 1 57 1035 1 77 1088 1 97 1135 2 18 1176 2 40 2600 712 0 60 766 0 87 823 1 11 882 1 34 942 1 55 1002 1 75 1058 1 95 1111 2 15 11...

Page 29: ...P RPM BHP RPM BHP RPM BHP RPM BHP 3 HP Field Supplied Drive Standard 3 HP Drive Hi Static 5 HP Drive 3200 757 1 20 811 1 36 864 1 50 915 1 64 964 1 77 1012 1 89 1059 2 02 1104 2 14 1149 2 26 1192 2 38...

Page 30: ...4 0 14 0 07 0 08 0 09 0 10 0 13 2500 0 11 0 16 0 08 0 09 0 10 0 11 0 14 2700 0 18 0 17 0 09 0 10 0 12 0 13 0 16 2900 0 25 0 19 0 10 0 11 0 13 0 14 0 18 3100 0 31 0 20 0 12 0 13 0 15 0 16 0 20 3300 0 3...

Page 31: ...1 95 BHP exceeds the maximum continuous BHP rating of the 1 5 HP motor The 2 HP motor is required 6 1268 RPM is within the range of the 2 HP drives 7 Using the 2 HP motor and drive 5 turns open will...

Page 32: ...0 676 0 651 Electric Heat Minimum Supply Air Size Tons Model Voltage Minimum Supply Air CFM Heater kW 9 18 24 36 54 078 6 5 XP 208 230 3 60 1950 1950 1950 1950 460 3 60 1950 1950 1950 1950 600 3 60 19...

Page 33: ...1 3 4 2 2 2 8 5 3800 2PE04703258 575 1 60 3 4 1050 1 2 9 1 5 1 9 4 3800 Electric Heat Multipliers Voltage kW Capacity Multipliers1 1 Electric heaters are rated at nominal voltage Use this table to det...

Page 34: ...e with AHRI 270 standard Octave Band Centerline Frequency Hz 125 250 500 1000 2000 4000 8000 078 6 5 XP 83 88 0 82 5 81 5 78 0 73 0 69 0 62 0 090 7 5 XP 83 89 5 83 5 82 0 78 0 72 5 68 0 60 5 102 8 5 X...

Page 35: ...49 6 50 60 E09 6 8 1 18 9 67 7 73 2 70 80 E18 13 5 2 37 5 90 9 96 4 100 100 E24 18 2 50 0 106 6 112 1 110 125 E36 25 5 2 70 8 132 6 138 1 150 150 230 15 6 83 1 21 4 1 5 6 0 5 5 0 0 None 44 1 49 6 50 6...

Page 36: ...3 5 2 37 5 114 1 119 6 125 125 E24 18 2 50 0 129 8 135 3 150 150 E36 25 5 2 70 8 155 8 161 3 175 175 E54 40 6 2 112 7 155 8 161 4 175 175 230 22 4 149 0 35 0 1 5 10 9 5 5 0 0 None 67 3 72 8 80 90 E18...

Page 37: ...0 E09 6 8 1 18 9 71 3 76 8 80 80 E18 13 5 2 37 5 94 5 100 0 100 100 E24 18 2 50 0 110 2 115 7 125 125 E36 25 5 2 70 8 136 2 141 7 150 150 230 15 6 83 1 21 4 1 5 9 6 5 5 0 0 None 47 7 53 2 60 60 E09 9...

Page 38: ...13 5 2 37 5 119 3 124 8 125 125 E24 18 2 50 0 135 0 140 5 150 150 E36 25 5 2 70 8 161 0 166 5 175 175 E54 40 6 2 112 7 161 0 167 9 175 175 230 22 4 149 0 35 0 1 5 16 1 5 5 0 0 None 72 5 78 0 90 100 E1...

Page 39: ...E09 6 8 1 18 9 77 7 83 2 80 90 E18 13 5 2 37 5 100 9 106 4 110 110 E24 18 2 50 0 116 6 122 1 125 125 E36 25 5 2 70 8 142 6 148 1 150 150 230 15 6 83 1 21 4 1 5 6 0 5 5 10 0 None 54 1 59 6 60 70 E09 9...

Page 40: ...8 13 5 2 37 5 124 1 129 6 125 150 E24 18 2 50 0 139 8 145 3 150 150 E36 25 5 2 70 8 165 8 171 3 175 175 E54 40 6 2 112 7 167 0 173 9 175 175 230 22 4 149 0 35 0 1 5 10 9 5 5 10 0 None 77 3 82 8 90 100...

Page 41: ...E09 6 8 1 18 9 81 3 86 8 90 90 E18 13 5 2 37 5 104 5 110 0 110 110 E24 18 2 50 0 120 2 125 7 125 150 E36 25 5 2 70 8 146 2 151 7 150 175 230 15 6 83 1 21 4 1 5 9 6 5 5 10 0 None 57 7 63 2 70 70 E09 9...

Page 42: ...13 5 2 37 5 129 3 134 8 150 150 E24 18 2 50 0 145 0 150 5 150 175 E36 25 5 2 70 8 171 0 176 5 175 200 E54 40 6 2 112 7 173 5 180 4 175 200 230 22 4 149 0 35 0 1 5 16 1 5 5 10 0 None 82 5 88 0 100 110...

Page 43: ...528195 YTG I 0513 Johnson Controls Unitary Products 43 Typical Wiring Diagrams XP078 150 Typical Wiring Diagrams Typical XP078 120 Heat Pump with without Electric Heat Wiring Diagram...

Page 44: ...528195 YTG I 0513 44 Johnson Controls Unitary Products Typical XP150 Heat Pump with without Electric Heat Wiring Diagram...

Page 45: ...1085 1080 38 25 262 195 266 357 184 150 124 169 204 250 090 7 5 XP 1095 1090 38 23 243 181 284 381 171 139 115 181 217 267 102 8 5 XP 1142 1137 38 25 5 282 210 276 370 197 161 133 175 211 259 120 10...

Page 46: ...528195 YTG I 0513 46 Johnson Controls Unitary Products XP078 150 Unit Dimensions XP078 120 XP150 See detail A for drain location See detail A for drain location...

Page 47: ...0 3 16 24 3 16 17 3 16 6 3 16 120 50 3 4 89 30 3 16 24 3 16 17 3 16 6 3 16 150 50 3 4 119 1 2 30 3 16 24 3 16 17 3 16 6 3 16 5 3 8 3 4 FPT XP078 150 Unit Clearances Direction Distance in Direction Dis...

Page 48: ...it Electrical Entry XP078 120 Unit Side Duct Openings Disconnect Swith Cover Power Entry 2 1 2 Control Entry 7 8 Power Entry 2 1 2 Convenience Outlet Cover Convenience Outlet Power Entry 7 8 FRONT Dot...

Page 49: ...eft Duct Opening Side Duct Dimensions Unit Model Number Dimension in A B C D 078 28 1 4 18 1 16 28 1 4 18 1 4 090 28 1 4 18 1 16 28 1 4 18 1 4 102 28 1 4 18 1 16 28 1 4 18 1 4 120 28 1 4 18 1 16 28 1...

Page 50: ...ons XP078 150 Roof Curb XP078 150 Transition Roof Curb 8 or 14 50 1 2 30 20 20 80 5 8 6 2 TYP INSULATED DECK UNDER COMPRESSOR SECTION INSULATED DECK UNDER CONDENSER SECTION FRONT RIGHT SUPPLY RETURN 7...

Page 51: ...2 UNIT BASE WOOD NAILER 8 MIN ABOVE FINISHED ROOF CURB FRAME INSULATION UNIT BASE RAILS COUNTERFLASHING CAN T STRIP INSULATION AND ROOFING MATERIAL ROOF DECK AND SUPPORT STRUCTURE 14 3 56 3 75 XP078 1...

Page 52: ...n 42 Slab Economizer 42 tall cabinet 2EE047058242 50 Slab Economizer 50 tall cabinet 2EE047057242 1 Barometric relief must be ordered separately and installed in duct work 2 Barometric relief or fresh...

Page 53: ...ust 1EH0408 Barometric Relief Hood 1EH0408 Barometric Relief Damper 2PE047032XX Power Exhaust 2EE04706024 Fresh Air Hood 2EE04706024 Fresh Air Damper 2EE04706024 Return Air Damper Field Installed Duct...

Page 54: ...s reserved Supersedes 528195 YTG H 0213 Johnson Controls Unitary Products 5005 York Drive Norman OK 73069 Slab Economizer End Return W Power Exhaust 2EE04705X24 Slab Economizer 1EH0409 Barometric Reli...

Reviews: