528195-YTG-I-0513
Johnson Controls Unitary Products
19
115°F
125°F
2125
77
98.9
10.0
41.2
36.0
26.8
-
-
-
90.2
11.1
44.1
31.8
25.3
-
-
-
72
89.2
9.9
60.4
50.3
40.1
30.0
-
-
81.3
11.0
58.2
48.0
37.8
27.6
-
-
67
79.6
9.8
79.6
64.5
53.4
43.3
33.2
-
72.4
10.9
72.4
62.0
50.4
40.2
30.0
-
62
73.4
9.7
73.4
73.4
65.6
55.4
45.3
35.2
66.2
10.8
66.2
66.2
66.2
52.3
42.2
32.0
2550
77
102.3
10.0
55.9
42.2
30.3
-
-
-
93.3
11.1
59.4
40.8
28.8
-
-
-
72
92.4
9.9
69.1
57.3
45.4
33.5
-
-
84.1
11.0
67.2
55.1
43.1
31.1
-
-
67
82.4
9.8
82.4
72.3
60.5
48.6
36.7
-
74.9
10.9
74.9
69.4
57.4
45.4
33.4
-
62
76.0
9.8
76.0
76.0
74.1
62.3
50.4
38.5
68.5
10.8
68.5
68.5
68.5
59.2
47.2
35.2
57
79.1
9.8
79.1
79.1
67.5
55.6
43.7
31.8
73.1
10.8
73.1
73.1
61.6
49.6
37.6
25.5
2975
77
105.8
10.1
70.7
48.4
33.8
-
-
-
96.4
11.2
74.8
49.9
32.3
-
-
-
72
95.5
10.0
77.9
64.3
50.6
37.0
-
-
86.9
11.0
76.1
62.2
48.4
34.6
-
-
67
85.1
9.9
85.1
80.1
67.5
53.8
40.2
-
77.3
10.9
77.3
76.9
64.5
50.6
36.8
-
62
78.5
9.8
78.5
78.5
82.7
69.1
55.5
41.8
70.7
10.8
70.7
70.7
70.7
66.1
52.3
38.5
57
81.8
9.8
81.8
81.8
75.3
61.6
48.0
34.4
75.6
10.9
75.6
75.6
69.2
55.3
41.5
27.7
3400
77
109.2
10.1
85.4
54.6
37.3
-
-
-
99.5
11.2
90.2
58.9
35.9
-
-
-
72
98.6
10.0
86.6
71.3
55.9
40.5
-
-
89.7
11.1
85.0
69.4
53.7
38.0
-
-
67
87.9
9.9
87.9
87.9
74.5
59.1
43.7
-
79.8
10.9
79.8
79.8
71.5
55.8
40.2
-
62
81.1
9.8
81.1
81.1
91.3
75.9
60.6
45.2
73.0
10.9
73.0
73.0
73.0
73.0
57.4
41.7
57
84.4
9.9
84.4
84.4
83.1
67.7
52.3
37.0
78.0
10.9
78.0
78.0
76.8
61.1
45.5
29.8
3825
72
100.3
10.0
93.9
76.9
60.0
43.0
-
-
91.0
11.1
91.0
75.1
57.8
40.5
-
-
67
89.4
9.9
89.4
89.4
79.9
63.0
46.0
-
81.0
11.0
81.0
81.0
76.9
59.6
42.3
-
62
82.5
9.9
82.5
82.5
87.6
70.7
53.7
36.8
74.0
10.9
74.0
74.0
74.0
64.6
47.3
30.0
57
85.9
9.9
85.9
85.9
85.2
68.3
51.3
34.4
79.1
10.9
79.1
79.1
78.5
61.2
43.9
26.6
4250
72
101.9
10.1
101.1
82.6
64.1
45.6
-
-
92.3
11.1
92.3
80.8
61.8
42.9
-
-
67
90.9
10.0
90.9
90.9
85.4
66.8
48.3
-
82.1
11.0
82.1
82.1
82.1
63.4
44.4
-
62
83.9
9.9
83.9
83.9
83.9
65.4
46.8
28.3
75.1
10.9
75.1
75.1
75.1
56.2
37.2
18.3
57
87.3
9.9
87.3
87.3
87.3
68.8
50.3
31.8
80.3
11.0
80.3
80.3
80.3
61.3
42.4
23.4
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
XP102 (8.5 Ton) (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65