![York Predator XP Series Technical Manual Download Page 23](http://html2.mh-extra.com/html/york/predator-xp-series/predator-xp-series_technical-manual_4151567023.webp)
528195-YTG-I-0513
Johnson Controls Unitary Products
23
115°F
125°F
3125
77
151.0
14.0
61.6
51.9
38.8
-
-
-
147.4
15.3
52.9
47.4
34.5
-
-
-
72
139.6
13.9
87.4
74.3
61.1
48.0
-
-
134.0
15.2
82.6
69.7
56.8
43.9
-
-
67
128.2
13.7
113.3
96.7
83.5
70.3
57.2
-
120.6
15.0
110.2
92.1
79.2
66.2
53.3
-
62
126.2
13.5
126.2
114.1
97.0
83.8
70.7
57.5
123.6
14.7
123.6
105.5
89.6
76.7
63.8
50.9
3750
77
156.0
14.1
73.1
57.9
42.8
-
-
-
150.7
15.4
68.1
53.1
38.2
-
-
-
72
144.2
13.9
97.8
82.6
67.5
52.4
-
-
136.9
15.2
92.8
77.9
63.0
48.1
-
-
67
132.4
13.8
122.5
107.4
92.2
77.1
62.0
-
123.1
15.1
117.6
102.7
87.8
72.9
57.9
-
62
130.4
13.5
130.4
122.3
107.2
92.1
77.0
61.9
126.4
14.8
126.4
114.3
99.4
84.5
69.6
54.7
57
127.3
13.6
127.3
121.7
106.6
91.5
76.4
61.3
122.8
14.9
122.8
114.5
98.1
83.1
68.2
53.3
4375
77
161.0
14.2
84.5
64.0
46.9
-
-
-
154.0
15.4
83.2
58.9
42.0
-
-
-
72
148.8
14.0
108.1
91.0
74.0
56.9
-
-
139.8
15.3
103.1
86.1
69.2
52.3
-
-
67
136.6
13.9
131.6
118.1
101.0
83.9
66.9
-
125.7
15.2
125.1
113.3
96.4
79.5
62.5
-
62
134.5
13.6
134.5
130.5
117.3
100.3
83.2
66.2
129.2
14.9
129.2
123.1
109.2
92.3
75.3
58.4
57
131.3
13.7
131.3
128.6
116.7
99.7
82.6
65.6
125.5
15.0
125.5
121.3
107.7
90.8
73.9
56.9
5000
77
166.0
14.2
95.9
70.0
51.0
-
-
-
157.3
15.5
98.3
64.7
45.8
-
-
-
72
153.4
14.1
118.4
99.4
80.4
61.4
-
-
142.8
15.4
113.3
94.3
75.4
56.5
-
-
67
140.8
13.9
140.8
128.8
109.8
90.7
71.7
-
128.2
15.3
128.2
124.0
105.0
86.1
67.1
-
62
138.7
13.7
138.7
138.7
127.5
108.5
89.5
70.5
132.0
15.0
132.0
132.0
119.0
100.1
81.1
62.2
57
135.4
13.7
135.4
135.4
126.8
107.8
88.8
69.8
128.2
15.1
128.2
128.2
117.4
98.5
79.5
60.6
5625
72
155.5
14.1
127.4
106.8
86.2
65.6
-
-
145.2
15.4
121.4
101.0
80.6
60.2
-
-
67
142.7
14.0
142.7
136.7
117.7
97.1
76.5
-
130.4
15.3
130.4
130.3
112.3
91.9
71.4
-
62
140.5
13.7
140.5
140.5
135.0
114.3
93.7
73.1
134.2
15.0
134.2
134.2
127.7
107.3
86.9
66.5
57
137.2
13.7
137.2
137.2
132.9
112.3
91.7
71.1
130.3
15.1
130.3
130.3
124.9
104.5
84.1
63.7
6250
72
157.5
14.1
136.4
114.2
92.0
69.8
-
-
147.6
15.4
129.6
107.7
85.8
63.9
-
-
67
144.6
14.0
144.6
144.6
125.6
103.4
81.2
-
132.7
15.3
132.7
132.7
119.5
97.6
75.7
-
62
142.4
13.7
142.4
142.4
142.4
120.2
98.0
75.8
136.4
15.0
136.4
136.4
136.4
114.5
92.6
70.7
57
139.0
13.7
139.0
139.0
139.0
116.8
94.6
72.4
132.5
15.1
132.5
132.5
132.5
110.6
88.7
66.8
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
XP150 (12.5 Ton) (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65