GENERAL
This instruction covers the installation of the following Stellar
ULTRA
high efficiency condensing units.
NOMENCLATURE
The outdoor condensing units are designed to be installed with
corresponding variable speed air handlers and a correspond-
ing coil with sweat connect lines. Each unit is factory charged
with refrigerant sufficient for the smallest indoor evaporator coil
plus 15 feet of field supplied vapor and liquid lines. A balanced
port hard shut-off TXV kit must be used for optimum system
performance.
SAFETY
Use this instruction in conjunction with the instruction for the
appropriate indoor evaporator coil, variable speed air handler and
other accessories. Read all instructions before installing the unit.
Installer should pay particular attention to the words:NOTE,
CAUTION and WARNING.
NOTES are intended to clarify or make the installation easier.
CAUTIONS are given to prevent equipment damage.
WARNINGS are given to alert the installer that personal injury
and/or equipment damage may result if installation procedures
are not handled properly.
INSPECTION
As soon as a unit is received, it should be inspected for possible
damage during transit. If damage is evident, the extent of the
damage should be noted on the carrier’s freight bill. A separate
request for inspection by the carrier’s agent should be made in
writing. See Form 50.15-NM for more information.
LIMITATIONS
The unit should be installed in accordance with all national and
local safety codes and the limitations listed below:
1. Limitations for the indoor unit, coil and appropriate acces-
sories must also be observed.
2. This unit
should not be installed with a single speed air
handler or furnace system.
3. The outdoor unit must not be installed with any ductwork in
the air stream. The outdoor fan is the propeller type and is
not designed to operate against any additional external
static pressure.
4. The unit should not be operated at outdoor temperatures
below 60
°
F.
The unit is not designed to operate with a
low ambient kit. Do not modify the control system to
operate with any type of low ambient kit.
5. Indoor evaporator coil orifice
must be removed prior to
the installation of a factory supplied balanced port TXV kit.
STELLAR ULTRA CONDENSING UNITS
SPLIT-SYSTEM COOLING
3 and 5 TONS
Supersedes: 550.37-N1Y (793)
550.37-N1Y (594)
035-10821
MODELS H1DS036, H1DS048 and H1DS060
H1DS036S06
H1DS048S06
H1DS060S06
Voltage Code
Refrigerant Line Connections
Nominal Cooling Capacity
H
036
S 06
1 DS
Product Category
Product Generation
Product Identifier
H = Condensing Unit
1 = Design Level
DS = 16.00 SEER Condensing Unit
036=36,000 BTUH
048=48,000 BTUH
060=60,000 BTUH
S = Sweat-Connect
06 = 208/230-1-60
®
INSTALLATION INSTRUCTION
CAUTION
THE ENCLOSED INSTALLATION INSTRUCTIONS AND ANY APPLICABLE
LOCAL, STATE, AND NATIONAL CODES INCLUDING, BUT NOT LIMITED
TO, BUILDING, ELECTRICAL, AND MECHANICAL CODES.
THIS PRO DUCT M UST BE INSTALLED IN STRICT COMPLIANCE W ITH
WARNING
OPERATION OF THE PRODUCT COULD CAUSE PERSONAL INJURY
O R P R O P E R T Y D A M A G E .
INCORRECT INSTALLATION MAY CREATE A CONDITION W HERE THE