Flow
m
3
/h
Return
air TS
ºC
Outdoor air temperature TS ºC
-10
-5
0
5
7
10
15
20
PT
PC
PT
PC
PT
PC
PT
PC
PT
PC
PT
PC
PT
PC
PT
PC
20
29.9
11
33.8
11.5
38.2
12
43.1
12.2
45.2*
12.8*
48.4
13.2
54.3
14.21
60.6
14.7
23
29.5
11.8
33.3
12.3
37.7
12.8
42.6
13.1
44.6
13.7
47.8
14.2
53.6
15.2
59.8
15.8
25
29.3
12.1
33.1
12.6
37.5
13.2
42.3
13.4
44.3
14.1
47.5
14.6
53.3
15.6
59.4
16.2
(Maximum)
10000
14
30.9
9.7
34.9
10.1
39.5
10.5
44.6
10.7
46.7
11.3
50.1
11.6
56.2
12.5
62.6
12.9
17
30.5
10.5
34.5
10.9
39.1
11.4
44.1
11.6
46.2
12.2
49.5
12.6
55.5
13.5
61.9
14
20
30.2
10.7
34.1
11.2
38.6
11.7
43.5
11.9
45.6
12.5
49
12.9
54.9
13.8
61.2
14.3
23
29.8
11.5
33.7
11.9
38.1
12.5
43
12.7
45.1
13.3
48.3
13.8
54.2
14.8
60.3
15.3
25
29.6
11.8
33.4
12.3
37.9
12.8
42.7
13.1
44.8
13.7
48
14.2
53.8
15.2
60
15.8
*
Data in accordance with Eurovent Rooftop program certification conditions
PT: Total Power; PC: Power absorbed by the compressor
WB: Wet-bulb temperature; TS: Dry bulb temperature.
1.12.6 ARH/ARD 060 Thermodynamic heat capacity
Flow
m
3
/h
Return
air TS
ºC
Outdoor air temperature TS ºC
-10
-5
0
5
7
10
15
20
PT
PC
PT
PC
PT
PC
PT
PC
PT
PC
PT
PC
PT
PC
PT
PC
(Minimum)
9500
14
38.7
11.4
43.7
11.8
49.5
12.4
55.9
12.6
58.6
13.2
62.8
13.7
70.4
14.7
78.5
15.2
17
38.2
12.3
43.2
12.8
49
13.4
55.25
13.7
57.9
14.3
62
14.8
69.6
15.9
77.6
16.5
20
37.8
12.6
42.7
13.1
48.4
13.7
54.6
14
57.2
14.7
61.3
15.2
68.7
16.3
76.6
16.9
23
37.3
13.5
42.2
14
47.8
14.7
53.8
15
56.4
15.7
60.5
16.2
67.8
17.4
75.6
18
25
37.1
13.9
41.9
14.4
47.5
15.1
53.5
15.4
56.1
16.1
60.1
16.7
67.4
17.9
75.2
18.5
(Nominal)
11500
14
39.3
11
44.4
11.5
50.2
12
56.7
12.2
59.4
12.8
63.7
13.3
71.4
14.2
79.6
14.7
17
38.8
11.9
43.8
12.4
49.7
13
56
13.3
58.7
13.9
63
14.4
70.6
15.4
78.7
16
20
38.3
12.2
43.2
12.7
49.1
13.3
55.3
13.6
58*
14.2*
62.2
14.7
69.7
15.8
77.7
16.3
23
37.8
13.1
42.8
13.6
48.4
14.2
54.6
14.5
57.2
15.2
61.4
15.7
68.8
16.9
76.7
17.5
25
37.6
13.4
42.5
14
48.1
14.6
54.3
14.9
56.9
15.6
61
16.2
68.4
17.3
76.2
18
(Maximum)
13500
14
39.7
10.7
44.8
11.2
50.7
11.7
57.2
11.9
60
12.5
64.3
12.9
72.1
13.9
80.4
14.4
17
39.2
11.6
44.3
12.1
50.2
12.6
56.6
12.9
59.3
13.5
63.6
14
71.3
15
79.4
15.6
20
38.7
11.9
43.8
12.4
49.6
12.9
55.9
13.2
58.6
13.8
62.8
14.3
70.4
15.3
78.5
15.9
23
38.2
12.7
43.2
13.2
48.9
13.8
55.2
14.1
57.8
14.8
62
15.3
69.5
16.4
77.5
17
25
38
13.1
43
13.6
48.6
14.2
54.8
14.5
57.5
15.2
61.6
15.7
69.1
16.9
77
17.5
*
Data in accordance with Eurovent Rooftop program certification conditions
PT: Total Power; PC: Power absorbed by the compressor
WB: Wet-bulb temperature; TS: Dry bulb temperature.
1.12.7 ARH/ARD 075 Thermodynamic heat capacity
Flow
m
3
/h
Return
air TS
ºC
Outdoor air temperature TS ºC
-10
-5
0
5
7
10
15
20
PT
PC
PT
PC
PT
PC
PT
PC
PT
PC
PT
PC
PT
PC
PT
PC
(Minimum)
11500
14
47.9
15.9
54.1
16.5
61.2
17.2
69.1
17.6
72.4
18.4
77.6
19.1
87
20.5
97
21.2
17
47.3
17.2
53.4
17.9
60.5
18.7
68.3
19.1
71.5
20
76.7
20.7
86
22.2
95.9
23
20
46.7
17.5
52.8
18.3
59.8
19.1
67.4
19.5
70.7
20.4
75.8
21.1
85
22.7
94.7
23.5
23
46.1
18.8
52.1
19.6
59
20.4
66.6
20.9
69.8
21.8
74.8
22.6
83.9
24.3
93.5
25.1
25
45.8
19.3
51.8
20.1
58.7
21
66.2
21.5
69.3
22.5
74.3
23.3
83.4
24.9
93
25.8
(Nominal)
13500
14
48.5
15.4
54.8
16
62.1
16.7
70
17.1
73.4
17.9
78.7
18.5
88.3
19.8
98.4
20.6
17
48
16.6
54.2
17.3
61.4
18.1
69.2
18.5
72.6
19.4
77.8
20
87.2
21.5
97.2
22.2
20
47.4
17
53.6
17.7
60.6
18.5
68.4
18.9
71.7*
19.8*
76.9
20.5
86.25
22
96.1
22.8
23
46.8
18.2
52.9
19
60
19.8
67.5
20.2
70.8
21.2
75.9
21.9
85.1
23.5
95
24.4
25
46.5
18.7
52.5
19.5
59.5
20.4
67.1
20.8
70.3
21.8
75.4
22.5
84.5
24.1
94.2
25
(Maximum)
16000
14
49
15
55.4
15.6
62.7
16.3
70.7
16.6
74.2
17.4
79.5
18
89.1
19.3
99.4
20
17
48.4
16.2
54.7
16.9
62
17.6
69.9
18
73.3
18.9
78.6
19.5
88.1
20.9
98.2
21.7
20
47.9
16.6
54.1
17.3
62.3
18
69.1
18.4
72.4
19.3
77.6
20
87
21.4
97
22.2
23
47.2
17.7
53.4
18.5
60.5
19.3
68.2
19.7
71.5
20.6
76.6
21.4
85.9
22.9
95.8
23.7
Installation manual
1
ARH/ARD Output 1.12
17
Summary of Contents for ARC 045
Page 1: ...ACTIVA SERIES ROOF TOP Air Conditioners Installation manual Ref N 40XXX...
Page 2: ......
Page 5: ...1 Installation manual...
Page 46: ......
Page 47: ...2 Unit installation data...
Page 52: ......