Horizontal Pipe Mounting
First attach the bracket to horizontal pipe with
U-bolt and nuts. Then, place the WN100 main unit
onto the bracket, and fasten them with four bracket
fastening bolts.
WN100
main
unit
Bolts for
fastening
bracket
U-bolt
Spring
washers for
fastening
bracket
Nuts for
fastening
bracket
Nuts for U-bolt
F0405.ai
Figure 4.5
Horizontal Pipe Mounting
4.3.1 Mounting on structures other than
2-inch pipe
If the bracket for 2-inch pipe is not appropriate for
the place you are to place WN100, please prepare
some kind of fixture. The fixture will be kind of
cantilever arms or cable tray that fit your facility
structure and meet the requirements described in
subsection 2.4 “Selecting the Installation Location”.
Put the fixture mentioned above in place, then
place the baseplate of the antivibration stage or the
WN100 main unit onto it, and fasten them with four
fastening bolts and nuts. In case of the antivibration
stage, install the WN100 main unit referring to the
subsection 4.2.1.
F0406.ai
Unit: mm
11
4
4-Ø7 HOLE
99
Figure 4.6
Dimensions of holes for fixing the
baseplate to the fixture