4-3
IM 04P01B01-17E
4
Commands
4.2
A List of Commands
Execution Modes and User Levels
Execution Modes
The recorder has two execution modes. Each command is specified to be used in a
particular execution mode. If you attempt to execute a command in a mode that is
different from the specification, a syntax error occurs. Use the DS command to switch to
the appropriate mode, and then execute the command. Query commands can be
executed in either mode.
• Basic Setting mode
Measurement/computation is stopped and settings are changed in this mode.
• Run mode
Run mode
collectively refers to Operation mode and Setting mode of the recorder.
User Levels
The administrator and user specifications in the table indicate the user level that is specified
using the login function for Ethernet communications. For details, see section 1.1.
Setting Commands
Command Function
Execution Mode
Administrator User Page
Name
SR
Sets the input range.
Run mode
Yes
No
4-10
VB
Sets the bias.
Run mode
Yes
No
4-11
VL
Sets the calibration correction (/CC1 option).
Run mode
Yes
No
4-11
SA
Sets the alarm.
Run mode
Yes
No
4-11
SN
Sets the unit.
Run mode
Yes
No
4-12
SC
Sets the chart speed.
Run mode
Yes
No
4-13
SD
Sets the date and time.
Run mode
Yes
No
4-13
VT
Sets the dot printing interval (dot model).
Run mode
Yes
No
4-13
SZ
Sets zone recording.
Run mode
Yes
No
4-13
SP
Sets the partial expanded recording.
Run mode
Yes
No
4-13
VR
Turns ON/OFF the recording on each channel.
Run mode
Yes
No
4-14
ST
Sets the tag.
Run mode
Yes
No
4-14
SG
Sets the message.
Run mode
Yes
No
4-14
SE
Sets the secondary chart speed
Run mode
Yes
No
4-14
(used by the remote control function (/R1 option)).
SV
Sets the moving average (dot model).
Run mode
Yes
No
4-14
SF
Sets the input filter (pen model).
Run mode
Yes
No
4-14
BD
Sets the alarm delay time.
Run mode
Yes
No
4-14
VF
Sets the brightness of the display (VFD) and internal
Run mode
Yes
No
4-14
illumination.
TD
Sets the DST.
Run mode
Yes
No
4-15
SS
Sets the DST. (Can be used on the
µ
R10000 with system Run mode
Yes
No
4-15
version 1.02 or earlier)
SO
Sets the computing equation (/M1 option).
Run mode
Yes
No
4-15
SK
Sets the computation constant (/M1 option).
Run mode
Yes
No
4-15
SJ
Sets the timer used in TLOG computation (/M1 option).
Run mode
Yes
No
4-15
VD
Sets the data display screen.
Run mode
Yes
No
4-16
CM
Sets the communication input data (/M1 option).
Run mode
Yes
No
4-18
FR
Sets the acquiring interval to the FIFO buffer.
Run mode
Yes
No
4-18
VH
Sets the batch number and lot number (/BT1 option).
Run mode
Yes
No
4-18
VC
Sets the batch comment (/BT1 option).
Run mode
Yes
No
4-18
VP
Turns Start printout/End printout ON/OFF (/BT1 option).
Run mode
Yes
No
4-19
VA
Sets the Start printout/End printout action (/BT1 option).
Run mode
Yes
No
4-19
VM
Sets the message format (/BT1 option).
Run mode
Yes
No
4-19
Yes: Command usable
No: Command not usable