4-27
IM 04P01B01-17E
Commands
4
When p1 =
FULL
µ
R10000: An integer between –30 to 30
(reference value: 1000)
µ
R20000: An integer between –50 to 50
(reference value: 1800)
Example
Adjust the 100% position. Set the record position
adjustment value to 25.
UA FULL,25
Description • Carry out the adjustment in the following
order: P1 = Hysteresis, ZERO, and then
FULL.
• Check the recorded result and correct the
record position adjustment value.
• To end the adjustment, execute the UY0
command. If you do not end the adjustment,
you cannot change the execution mode.
• The unit for p2 is dot (0.1 mm).
UG
Sets the Setting mode menu
selection.
Syntax
UG p1,p2,p3,p4,p5,p6,p7,p8,p9,p10
<terminator>
p1
Range (ON, OFF)
p2
Bias (ON, OFF)
p3
Alarm (ON, OFF)
p4
Units (ON, OFF)
p5
Chart speed (ON, OFF)
p6
Other (ON, OFF)
p7
Calibration correction (ON, OFF) (/CC1
option)
p8
Computation (ON, OFF) (/M1 option)
p9
Batch name (ON, OFF) (/BT1 option)
p10
Batch details (ON, OFF) (/BT1 option)
Query
UG?
Example
Display all menus.
UG ON,ON,ON,ON,ON,ON,ON,ON,ON,ON
Description • Parameter p7 can be specified on models with
the calibration correction (/CC1 option).
• Parameter p8 can be specified on models with
the computation function (/M1 option).
• Parameters p9 and p10 can be specified on
models with the header printout (/BT1 option).
Note
Parameters p7 and higher are skipped when no
options are installed.
UH
Sets the FUNC key menu
selection.
Syntax
UH p1,p2,p3,p4,p5<terminator>
p1
Manual printout (ON, OFF)
p2
Setup printout (ON, OFF)
p3
Message printout (ON, OFF)
p4
Buffer clear (ON, OFF)
p5
Periodic printout (ON, OFF)
Query
UH?
Example
Display all menus.
UH ON,ON,ON,ON,ON
UE
Selects enable/disable for Start
printout/End printout and
message format (/BT1 option).
When using Start printout/End printout
Syntax
UE p1,p2,p3,p4<terminator>
p1
Use of Start printout/End printout (USE)
p2
Number of digits for lot number (4, 6, NOT)
p3
Use/Not use Start printout 2/End printout 2
(USE, NOT)
p4
Use/Not use message format (USE, NOT)
Query
UE?
Example
Perform Start printout/End printout, set 6 digits
for lot number, use Start printout 2/End printout 2
and message format.
UE USE,6,USE,USE
Description • Set the lot number using the VH command.
• Set the message format using the VM
command.
When not using Start printout/End printout
Syntax
UE p1,p2<terminator>
p1
Start printout/End printout not used (NOT)
p2
Use/Not use message format (USE, NOT)
Query
UE?
Example
Use message format but do not use Start
printout/End printout.
UE NOT,USE
Description Set the message format using the VM command.
YE
Exits from Basic Setting mode.
When the YE command is executed, communication is
dropped.
Syntax
YE p1
<terminator>
p1
Apply/Discard the settings
STORE
Apply the settings
ABORT
Discard the settings
Example
Apply the basic settings.
YE STORE
Description Applies the settings changed with the basic
setting commands.
XE
Exits from Basic Setting mode.
Communication is not dropped when the XE command is
executed.
Syntax
XE p1
<terminator>
p1
Apply/Discard the settings
STORE
Apply the settings
ABORT
Discard the settings
Example
Apply the basic settings.
XE STORE
Description The settings specified by the following
commands and saved using the XE command
take effect after the recorder is power cycled.
YS, YB, YA, YN, YD, YQ, and YK
4.5 Basic Setting Commands