4-13
IM 04P01B01-01E
Common Operations for Setting Functions and Setup Menu
4.3 Menu Structure, Settings, and List of Default Values
1
2
3
4
5
6
7
8
9
10
11
12
App
Index
Setup Item
Pen/Dot
Selectable Range or Selections
Default Value
Ethernet (/C7 option)
Ethernet > Host > Host
-
64 characters or less
Blank
Ethernet > Host > Domain
-
64 characters or less
Blank
Ethernet > Local IP > A
-
IP address
0.0.0.0
Ethernet > Local IP > M
-
IP address (Subnet mask)
0.0.0.0
Ethernet > Local IP > G
-
IP address (Default gateway)
0.0.0.0
Ethernet > DNS > DNS
-
On/Off
Off
Ethernet > DNS > P
-
IP address (Primary DNS sever)
0.0.0.0
Ethernet > DNS > S
-
IP address (Secondary DNS sever)
0.0.0.0
Ethernet > DNS > Suffix_P
-
Primary domain suffix
Blank
Ethernet > DNS > Suffix_S
-
Secondary domain suffix
Blank
Ethernet > Login > Login
-
Use/Not
Not
Ethernet > LoginSet > Level
-
Admin/User1 to User6
Admin
Ethernet > LoginSet > Register
-
On/Off
Admin and User1
are On
Ethernet > LoginSet > User
-
16 characters or less
Admin: admin
User1 to 6: user1
to user6
Ethernet > LoginSet > Password
-
4 characters or less
Administrator: 0
User1 to 6: 1 to 6
Ethernet > Timeout > Timeout
-
On/Off
Off
Ethernet > Timeout > Duration
-
1 to 120 min
1 min
Ethernet > K. Alive > Keep alive
-
On/Off
On
Calibration (/CC1 option)
Calibration > CH
-
01 to 06
01
Calibration > Mode
-
Revise Value, Abs. Value
Revise Value
Calibration > Point
-
2 to 16
2
Cust. menu > Cust. menu
-
Not/Use
Not
Cust. menu > Password
-
Numbers and spaces within 4 digits
Blank
Cust. menu > P_Adj
-
On/Off
Off
Select menu > Set mode > Range
-
On/Off
On
Select menu > Set mode > Bias
-
On/Off
On
Select menu > Set mode > Alarm
-
On/Off
On
Select menu > Set mode > Unit
-
On/Off
On
Select menu > Set mode > Chart speed
-
On/Off
On
Select menu > Set mode > Aux
-
On/Off
On
Select menu > Set mode > Calibration
-
On/Off
On
Select menu > Set mode > Math
-
On/Off
On
Select menu > Set mode > Batch name
-
On/Off
On
Select menu > Set mode > Batch detail
-
On/Off
On
Select menu > Function > Manual print
-
On/Off
On
Select menu > Function > Setup list
-
On/Off
On
Select menu > Function > Message
-
On/Off
On
Select menu > Function > Buffer clear
-
On/Off
On
Select menu > Function > Periodic
-
On/Off
On
Select menu > Function > Data save
-
On/Off
On
Select menu > Function > Data replay
Dot Model On/Off
On
Select menu > Function > SD eject
-
On/Off
On
Batch (/BT1)
Batch > Batch
-
Not/Use
Not
Batch > Lot No.
-
4/6/Not
4
Batch > Dual comment
-
Not/Use
Not
Batch > MSG format
-
Not/Use
Not
SD memory card (/EM1 option)
Load param > File
-
Search text
-
Load param > Mode
-
Setup+Set/Setup
Setup+Set
Format > Label
-
Up to 11 characters
-
Format > Execute
-
Execute
Execute
Adjustment
P_Adj > P_Adj
Dot Model Hysteresis/Zero/Full
Hysteresis
Pen Model Zero/Full
Zero