<2. Handling Cautions>
2-10
IM 01C27B01-01EN
(3) Operation
CAUTION
• The temperature and pressure of fluid should
be maintained at levels that are consistent
with normal operating conditions.
• The ambient temperature should be
maintained at a level that is consistent with
normal operating conditions.
• Please take care to prevent water hammer
and the like from inducing excessive
pressures in pipes and valves. If phenomena
are likely, install a safety valve or take
some other appropriate measure to prevent
pressure from exceeding PS.
• Take appropriate measures at the device or
system level to protect transmitters if they
are to be operated near an external heat
source.
2.11 Low Voltage Directive
Applicable standard:
EN61010-1, EN61010-2-030
(1) Pollution Degree 2
"Pollution degree" describes the degree to
which a solid, liquid, or gas which deteriorates
dielectric strength or surface resistivity is
adhering. " 2 " applies to normal indoor
atmosphere. Normally, only non-conductive
pollution occurs. Occasionally, however,
temporary conductivity caused by condensation
must be expected.
(2) Installation Category I
(Anticipated transient overvoltage 330 V)
"Overvoltage category (Installation category)"
describes a number which defines a transient
overvoltage condition. It implies the regulation
for impulse withstand voltage. " I " applies to
electrical equipment which is supplied from the
circuit when appropriate transient overvoltage
control means (interfaces) are provided.
(3) Indoor/Outdoor use
It can be used in indoors and outdoors.
(4) Altitude of installation site
Max. 2,000 m above sea level
2.12 Regulatory Compliance
for Radio and
Telecommunication
Please confirm that a installation region fulfils a
standards, require additional regulatory information
and approvals, contact to Yokogawa Electric
Corporation.
2.12.1 Radio Equipment Directive (RE)
Hereby, Yokogawa Electric Corporation declares
that the radio equipment type EJX
B is in
compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is
available at the following Internet address:
http://www.yokogawa.com/fld/
2.12.2 FCC compliance
This equipment contains transmitter module FCC ID:
SGJ-WFC001
*1
SGJ-WFC014
*2
*1: Only applicable for selecting output signal code -L.
*2: Only applicable for selecting output signal code -1.
This device complies with Part 15 of FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2)
this device must accept any interference received,
including interference that may cause undesired
operation of this device.
Co-located:
This transmitter must not be co-located or operated
in conjunction with any other antenna or transmitter.
FCC WARNING:
Changes or modifications not expressly approved
by the party responsible for compliance could void
the user’s authority to operate the equipment.
RF Exposure Compliance:
This equipment complies with FCC radiation
exposure limits set forth for an uncontrolled
environment and meets the FCC radio frequency
(RF) Exposure Guidelines. This equipment should
be installed and operated keeping the radiator at
least 20 cm or more away from person’s body.