10.3- Cooling with Heat Exchanger ;
You can see the minimum cooling water flow rate for heat exchanger types below.
Maximum cooling water inlet temperature must be 30ºC.
Flow Diagram
Heat Exchanger (Shaft End Pump)
Flow Diagram
Heat Exchanger (External Motor Pump)
Cooling Options
1 - H ; 4 cm/rev pump
B ; 16 cm/rev pump
2 - Shaft end of gearbox
3 - 3 bar pressure valve
4 - Bypass valve (optional)
5 - 20 µ oil filter
6 - Pressure differential led (optional)
7 - Bypass valve (optional)
8 - Flow switch (optional)
1 - 4 cm/rev pump
2 - 0,37 kW, 1400 rpm pump motor
3 - 3 bar pressure valve
4 - Bypass valve (optional)
5 - 20 µ oil filter
6 - Pressure differential led (optional)
7 - Bypass valve (optional)
8 - Flow switch (optional)
Heat Exchanger Type
Cooling Power [kW]
Oil Flow Rate [lt/d]
Pomp Power [kW]
Min. Cooling Water Flow
Rate [lt/d]
E1
1,5
5,6
0,18
2,2
E2
3,0
5,6
0,18
5,6
E3
5,0
11,5
0,37
7,2
E4
10
22,4
0,75
14
E5
20
46,2
1,5
29
E6
30
72,8
2,2
43
E7
45
98
3,0
65
E8
60
114
3,0
80
E9
80
136
7,5
115
E10
100
173
7,5
140