60
10.4- Cooling with Air / Oil Heat Exchanger ;
You can find technical informations about air / oil heat exchangers below. Technical
informations are valid for 20ºC ambient temperature.
Flow Diagram
Air / Oil Heat Exchanger (Shaft End Pump)
Flow Diagram
Air / Oil Heat Exchanger (External Motor Pump)
Cooling Options
1 - Shaft end pump
2 - Shaft end of gearbox
3 - 3 bar pressure valve
4 - Bypass valve (optional)
5 - Pressure differential led (optional)
6 - 20 µ
oil filter
7 - Bypass valve (optional)
8 - Air / oil heat exchanger
9 - Flow switch (optional)
1 - External pump
2 - Pump motor
3 - 3 bar pressure valve
4 - Bypass valve (optional)
5 - Pressure differential led (optional)
6 - 20 µ
oil filter
7 - Bypass valve (optional)
8 - Air / oil heat exchanger
9 - Flow switch (optional)
Air / Oil H. Exchanger Type
Cooling Capacity [kW]
Oil Volume [lt/m]
Pump Motor Power [kW]
R1
6,0
62
2,2
R2
9,5
62
2,2
R3
17,5
98
3,0
R4
25
98
3,0
R5
29,5
98
3,0
R6
45
98
3,0
R7
60
160
7,5
R8
75
160
7,5
Operating Instructions
H Series
YILMAZ REDÜKTÖR