38
5.2- Storage
If the gear unit or geared motor will be stored up to 3 years refer to the following
instructions;
With Packing ;
- Use corrosion protection oil for the output shaft and connection surfaces like flange
surface or foot assembling surfaces. Seal the unit in a plastic wrap and pack it in container.
A moisture indicator should be placed around the container to observe the moisture.
Relative atmospheric humidity should not exceed 50%. The container should be kept
under roof which protects from snow and rain. Under this condition the gear unit can be
stored up to 3 years with regular checks. The ambient temperature should be between - 5
to + 60 Celsius degrees
Without Packing ;
- Use protection oil for the output shaft and connection surfaces like flange surface or foot
assembling surfaces. If no packing is used and the gearbox is stored without packing, the
ambient temperature should be b 5 to + 60 Celsius degrees. The gearbox must
be kept under enclosed roof with constant temperature and constant humidity which is not
exceeding 50 %. The storage should be free of dust and dirt and ventilated with filter. If the
gearbox is stored without packing it is recommended not to store more than 2 years and
regular checking during this time is recommended. If stored in open areas protect against
insect damage.
6- Installing The Gear Unit
6.1- Before You Start ;
- Observe the gear unit for damages of storage or transportation. If any damage please
contact YILMAZ REDUKTOR.
- Be sure that you have all the equipment necessary for installing like; Spanners, torque
wrench, shims and distance rings, fixing devices for input and output elements, lubricant,
bolt adhesive etc.
- This manual is not for 2014/34/EU (ATEX) conforming gear units. For 2014/34/EU con-
forming gear units refer to the ATEX range manual. ATEX conforming gear units have
name plates indicating the zone and the temperature class and are different from standard
type geared units. Therefore standard units can not be installed on potentially explosive
atmospheres.
Checking
Operating Instructions
H Series
YILMAZ REDÜKTÖR