39
6.2- Check the Shaft Dimensions to Fit
6.3- Check the Ambient Temperature ;
The ambient temperature must be b5 celsius to +40 celsius for standard
type gear units. If there is different ambient conditions please contact
YILMAZ REDUKTOR for special solutions.
6.4- Check the Voltage Supply ;
The standard geared motors are supplied with 230/400 V 50/60Hz. up to 3kW
including 3kW and 400/690 V 50/60 Hz. over 3kW and is indicated on the motors
name plate unless it is differently ordered. In case of only gear unit is supplied from
YILMAZ please observe the name plate of the electric motor and the instructions of
the supplier. Check the basic electric connection diagrams given on next pages. Use
experienced electric technician.
Using wrong connection or voltage can damage the electric motor or environment.
Mounting
Type
Hollow
Output
Shaft Dia.
[mm]
Hollow
Output
Shaft
Tolerance.
(H8)
Solid
Output
Shaft Dia.
[mm]
Solid
Output
Shaft Dia.
(DIN 748)
(m6)
Type
Hollow
Output
Shaft Dia.
[mm]
Hollow
Output
Shaft
Tolerance.
(H8)
Solid
Output
Shaft Dia.
[mm]
Solid
Output
Shaft Dia.
(DIN 748)
(m6)
H.03
60
+0.04
0
70
+0.04
+0.02
H.13
190
+0.05
0
200
+0.05
+0.02
H.04
80
+0.03
0
80
+0.03
+0.01
H.14
210
+0.05
0
220
+0.05
+0.02
H.05
95
+0.04
0
100
+0.04
+0.01
H.15
230
+0.05
0
230
+0.05
+0.02
H.06
105
+0.04
0
110
+0.04
+0.01
H.16
240
+0.05
0
240
+0.05
+0.02
H.07
115
+0.04
0
120
+0.04
+0.01
H.17
-
-
250
+0.05
+0.02
H.08
125
+0.04
0
130
+0.04
+0.02
H.18
-
-
270
+0.05
+0.02
H.09
135
+0.04
0
140
+0.04
+0.02
H.19
-
-
290
+0.05
+0.02
H.10
150
+0.04
0
160
+0.04
+0.02
H.20
-
-
300
+0.05
+0.02
H.11
165
+0.04
0
170
+0.04
+0.02
H.21
-
-
320
+0.05
+0.02
H.12
180
+0.04
0
180
+0.04
+0.02
H.22
-
-
340
+0.05
+0.02
Operating Instructions
H Series
YILMAZ REDÜKTÖR