6. Operating with DeviceNet Communications
83
• Output (Inverter
→
Master) Instance 155 (9B Hex)
Fnc. Code 1 = 1
Fnc. Code 2 = 0
The data specified in
bytes 6 and 7 will be writ-
ten to the register speci-
fied in bytes 4 and 5.
Fnc. Code 1 = 1
Fnc. Code 2 = 1
Nothing will be executed.
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Fault-
ed
Warn-
ing
Ready
At Ref-
erence
Reset
Rev
Run-
ning
ZSP
Run-
ning
1
Termi-
nal P2
Termi-
nal P1
Termi-
nal
MA*
Local/
Re-
mote
Fnc.
Code 2
Fnc.
Code 1
UV
OPE
2
Speed Actual (Low Byte)
3
Speed Actual (High Byte)
4
Register Number (Low Byte)
5
Register Number (High Byte)
6
Register Data (Low Byte)
7
Register Data (High Byte)
Data
Name
Contents
Byte 0,
bit 0
Running
Indicates the Inverter’s operating status.
0: Stopped.
1: Operating forward, operating in
reverse, or applying DC injection
braking.
Status of Func-
tion Code 1
(Byte 1, bit 1)
Status of Func-
tion Code 2
(Byte 1, bit 2)
Function