![YASKAWA Varispeed V7 Instruction Manual Download Page 111](http://html1.mh-extra.com/html/yaskawa/varispeed-v7/varispeed-v7_instruction-manual_3554366111.webp)
110
* These faults are displayed only when they have been operated through
DeviceNet communications. There are no corresponding external input ter-
minals.
5300
OPR
Operator not connected
7500
BUS
Inverter communications error
9000
EF3
External fault (input terminal S3)
EF4
External fault (input terminal S4)
EF5
External fault (input terminal S5)*
EF6
External fault (input terminal S6)*
EF7
External fault (input terminal S7)*
EF0
External fault from communications
DeviceNet
Fault Code
(Hex)
Operator
Fault Dis-
play
Meaning