226
* 1. Temperature during shipping (for short period).
* 2. For details, refer to
Reducing Motor Noise or Leakage Current (n080)
on
page 151.
* 3. There is no corresponding external output terminal.
Status
Indica-
tors
RUN, ALARM, MS, and NS provided as standard indicators
Digital
Opera-
tor
(JVOP
-140)
Provided for monitor frequency reference, output frequency, output cur-
rent
Terminals
Main circuit: screw terminals
Control circuit: plug-in screw terminal
Wiring Dis-
tance
between
Inverter and
Motor
100 m (328 ft) or less
*2
Enclosure
Open chassis IP20, Open chassis IP20 (top closed type), or enclosed
wall-mounted NEMA 1 (TYPE 1)
Cooling Method
Cooling fan is provided for the following models:
200 V, 0.75 kW or larger Inverters (3-phase)
200 V, 1.5 kW or larger Inverters (single-phase)
Other models are self-cooling.
Ambient
Temperature
Open chassis IP20:
−
10 to 50
°
C (14 to 122
°
F)
Open chassis IP20 (top closed type) and enclosed wall-mounted NEMA 1
(TYPE 1):
−
10 to 40
°
C (14 to 105
°
F) (not frozen)
Humidity
95% or less (non-condensing)
Storage Tem-
perature
−
20 to 60
°
C (
−
4 to 140
°
F)
Location
Indoor (free from corrosive gases or dust)
Elevation
1,000 m (3,280 ft) or less
Vibration
Up to 9.8 m/S
2
(1G) at 10 to less than 20 Hz,
up to 2 m/S
2
(0.2G) at 20 to 50 Hz
Voltage Class
200 V single-/3-phase
Model
CIMR-
V7
*1
C
3-
phase
20P1
20P2
20P4
20P7
21P5
22P2
23P7
25P5
27P5
Single-
phase
B0P1
B0P2
B0P4
B0P7
B1P5
B2P2
B3P7
-
-
O
the
r F
u
ncti
ons
Indi
ca
tion
s
E
nv
ironme
nt
al
Co
ndi
tion
s