7.6 Convenient Function to Use during Trial Operation
7.6.3 Test without a Motor
7-28
Motor Information and Encoder Information
The motor and encoder information is used during tests without a motor. The source of the
information depends on the device connection status.
•
Rotary Servomotor
If you use fully-closed loop control, the external encoder information is also used.
•
Linear Servomotors
Motor Connection
Status
Information That Is Used
Source of Information
Connected
Motor information
•
Rated motor speed
•
Maximum motor speed
Information in the motor that is connected
Encoder information
•
Encoder resolution
•
Encoder type
Not connected
Motor information
•
Rated motor speed
•
Maximum motor speed
•
Setting of Pn000 = n.X
(Rotary/Linear Servo-
motor Startup Selection When Encoder Is Not Con-
nected)
•
Rated motor speed and maximum motor speed
The values previously saved in the SERVOPACK will
be used for the rated motor speed and maximum
motor speed.
Use the motor displays (Un020: Rated Motor Speed
and Un021: Maximum Motor Speed) to check the
values.
Encoder information
•
Encoder resolution
•
Encoder type
•
Encoder resolution: Setting of Pn00C = n.
X
(Encoder Resolution for Tests without a Motor)
•
Encoder type: Setting of Pn00C = n.
X
(Encoder
Type Selection for Tests without a Motor)
External Encoder Connection
Status
Information That Is
Used
Source of Information
Connected
External encoder infor-
mation
•
Resolution
•
Encoder type
Information in the external encoder that is con-
nected
Not connected
•
Resolution: 256
•
Encoder type: Incremental encoder
Motor Connection
Status
Information That Is Used
Source of Information
Connected
Motor information
Information in the motor that is connected
Linear encoder informa-
tion
•
Resolution
•
Encoder pitch
•
Encoder type
Information in the linear encoder that is connected
Not connected
Motor information
Setting of Pn000 = n.X
(Rotary/Linear Servomotor
Startup Selection When Encoder Is Not Connected)
Linear encoder informa-
tion
•
Resolution
•
Encoder pitch
•
Encoder type
•
Resolution: 256
•
Encoder pitch: Setting of Pn282 (Linear Encoder Scale
Pitch)
•
Encoder type: Setting of Pn00C = n.
X
(Encoder
Type Selection for Tests without a Motor)