14.1 List of Parameters
14.1.2 List of Parameters
14
Parameter Li
s
t
s
14-31
Pn51E
2
Position Deviation Over-
flow Warning Level
10 to 100
1%
100
All
Immedi-
ately
Setup
Pn520
4
Position Deviation Over-
flow Alarm Level
1 to
1,073,741,823
1 refer-
ence
unit
524288
0
All
Immedi-
ately
Setup
Pn522
4
Positioning Completed
Width
0 to
1,073,741,824
1 refer-
ence
unit
7
All
Immedi-
ately
Setup
Pn524
4
Near Signal Width
1 to
1,073,741,824
1 refer-
ence
unit
107374
1824
All
Immedi-
ately
Setup
Pn526
4
Position Deviation Over-
flow Alarm Level at
Servo ON
1 to
1,073,741,823
1 refer-
ence
unit
524288
0
All
Immedi-
ately
Setup
Pn528
2
Position Deviation Over-
flow Warning Level at
Servo ON
10 to 100
1%
100
All
Immedi-
ately
Setup
Pn529
2
Speed Limit Level at
Servo ON
0 to 10,000
1 min
-1
10000
Rotary
Immedi-
ately
Setup
Pn52A
2
Multiplier per Fully-
closed Rotation
0 to 100
1%
20
Rotary
Immedi-
ately
Tuning
Pn52B
2
Overload Warning Level
1 to 100
1%
20
All
Immedi-
ately
Setup
Pn52C
2
Base Current Derating
at Motor Overload
Detection
10 to 100
1%
100
All
After
restart
Setup
Pn52F
2
Monitor Display at
Startup
0000 hex to
0FFF hex
−
0FFF
hex
All
Immedi-
ately
Setup
Pn530
2
Program Jogging-
Related Selections
0000 hex to
0005 hex
−
0000
hex
All
Immedi-
ately
Setup
Pn531
4
Program Jogging Travel
Distance
1 to
1,073,741,824
1 refer-
ence
unit
32768
All
Immedi-
ately
Setup
Pn533
2
Program Jogging Move-
ment Speed
1 to 10,000
Rotary:
1 min
-1
Direct
Drive:
0.1 min
-1
500
Rotary
Immedi-
ately
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Program Jogging Operation Pattern
0
(Waiting time in Pn535
→
Forward by travel distance in Pn531)
×
Number of
movements in Pn536
1
(Waiting time in Pn535
→
Reverse by travel distance in Pn531)
×
Number of
movements in Pn536
2
(Waiting time in Pn535
→
Forward by travel distance in Pn531)
×
Number of
movements in Pn536
(Waiting time in Pn535
→
Reverse by travel distance in Pn531)
×
Number of
movements in Pn536
3
(Waiting time in Pn535
→
Reverse by travel distance in Pn531)
×
Number of
movements in Pn536
(Waiting time in Pn535
→
Forward by travel distance in Pn531)
×
Number of
movements in Pn536
4
(Waiting time in Pn535
→
Forward by travel distance in Pn531
→
Waiting time
in Pn535
→
Reverse by travel distance in Pn531)
×
Number of movements in
Pn536
5
(Waiting time in Pn535
→
Reverse by travel distance in Pn531
→
Waiting time
in Pn535
→
Forward by travel distance in Pn531)
×
Number of movements in
Pn536
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)