14.1 List of Parameters
14.1.2 List of Parameters
14
Parameter Li
s
t
s
14-27
Pn510
2
Output Signal Selec-
tions 3
0000 hex
to 0666
hex
−
0000
hex
All
After
restart
Setup
−
Pn512
2
Output Signal Inverse
Settings
0000 hex to
1111 hex
−
0000
hex
All
After
restart
Setup
Pn513
2
Output Signal Inverse
Settings 2
0000 hex to
0011 hex
−
0000
hex
All
After
restart
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
/NEAR (Near Output) Signal Allocation
Reference
0
Disabled (the above signal output is not used).
1
Output the signal from the CN1-25 or CN1-26 output terminal.
2
Output the signal from the CN1-27 or CN1-28 output terminal.
3
Output the signal from the CN1-29 or CN1-30 output terminal.
4
Output the signal from the CN1-37 output terminal.
5
Output the signal from the CN1-38 output terminal.
6
Output the signal from the CN1-39 output terminal.
n.
X
Reserved parameter (Do not change.)
n.
X
/PSELA (Reference Pulse Input Multiplication Switching Output) Signal
Allocation
Reference
0 to 6
The allocations are the same as the /NEAR (Near) signal alloca-
tions.
n.X
Reserved parameter (Do not change.)
n.
X
Output Signal Inversion for CN1-25 and CN1-26 Terminals
0
The signal is not inverted.
1
The signal is inverted.
n.
X
Output Signal Inversion for CN1-27 and CN1-28 Terminals
0
The signal is not inverted.
1
The signal is inverted.
n.
X
Output Signal Inversion for CN1-29 and CN1-30 Terminals
0
The signal is not inverted.
1
The signal is inverted.
n.X
Output Signal Inversion for CN1-37 Terminal
0
The signal is not inverted.
1
The signal is inverted.
n.
X
Output Signal Inversion for CN1-38 Terminal
0
The signal is not inverted.
1
The signal is inverted.
n.
X
Output Signal Inversion for CN1-39 Terminal
0
The signal is not inverted.
1
The signal is inverted.
n.
X
Reserved parameter (Do not change.)
n.X