14.2 Parameter Recording Table
14-39
14
Parameter Li
s
t
s
Pn48E
10
Polarity Detection Range
Immediately
Pn490
100
Polarity Detection Load
Level
Immediately
Pn495
100
Polarity Detection Confir-
mation Force Reference
Immediately
Pn498
10
Polarity Detection Allowable
Error Range
Immediately
Pn49F
0
Speed Ripple Compensa-
tion Enable Speed
Immediately
Pn501
10
Zero Clamping Level
Immediately
Pn502
20
Rotation Detection Level
Immediately
Pn503
10
Speed Coincidence Detec-
tion Signal Output Width
Immediately
Pn506
0
Brake Reference-Servo
OFF Delay Time
Immediately
Pn507
100
Brake Reference Output
Speed Level
Immediately
Pn508
50
Servo OFF-Brake Com-
mand Waiting Time
Immediately
Pn509
20
Momentary Power Interrup-
tion Hold Time
Immediately
Pn50A
2100 hex
Input Signal Selections 1
After restart
Pn50B
6543 hex
Input Signal Selections 2
After restart
Pn50C
8888 hex
Input Signal Selections 3
After restart
Pn50D
8888 hex
Input Signal Selections 4
After restart
Pn50E
3211 hex
Output Signal Selections 1
After restart
Pn50F
0000 hex
Output Signal Selections 2
After restart
Pn510
0000 hex
Output Signal Selections 3
After restart
Pn512
0000 hex
Output Signal Inverse Set-
tings
After restart
Pn513
0000 hex
Output Signal Inverse Set-
tings 2
After restart
Pn514
0000 hex
Output Signal Selections 4
After restart
Pn515
8888 hex
Input Signal Selections 6
After restart
Pn516
8888 hex
Input Signal Selections 7
After restart
Pn517
0654 hex
Output Signal Selections 5
After restart
Pn51B
1000
Motor-Load Position Devia-
tion Overflow Detection
Level
Immediately
Pn51E
100
Position Deviation Over-
flow Warning Level
Immediately
Pn520
5242880
Position Deviation Over-
flow Alarm Level
Immediately
Pn522
7
Positioning Completed
Width
Immediately
Pn524
1073741824
Near Signal Width
Immediately
Pn526
5242880
Position Deviation Over-
flow Alarm Level at Servo
ON
Immediately
Pn528
100
Position Deviation Over-
flow Warning Level at Servo
ON
Immediately
Pn529
10000
Speed Limit Level at Servo
ON
Immediately
Continued on next page.
Continued from previous page.
Parameter
No.
Default Setting
Name
When
Enabled