2.2 Speed Ripple Compensation
2.2.3 Setting Parameters
2-12
Speed Ripple Compensation Warnings
The speed ripple compensation value is specific to each Servomotor. If you replace the Servo-
motor while speed ripple compensation is enabled, an A.942 warning (Speed Ripple Compen-
sation Information Disagreement) will occur to warn you.
If an A.942 warning occurs, either reset or disable speed ripple compensation from the Sig-
maWin+.
You can also disable detection of this warning with the following parameter.
Parameter
Description
When
Enabled
Classifi-
cation
Pn423
n.
0
(default setting)
Detect A.942 alarms.
After
restart
Setup
n.
1
Do not detect A.942 alarms.
S
etting of Pn424
(Ripple
Compen
s
ation
Enable
S
peed)
Time
S
peed reference/
feedback
s
peed
Di
s
abled
Enabled
Di
s
abled
Enabled
Di
s
abled
Ripple
compen
s
ation