1.2 Forcing the Motor to Stop
1.2.2 Setting the FSTP (Forced Stop Input) Signal
1-13
1
Application Function
s
Pn597
n.
003
Allocate the signal to CN1-3.
After
restart
Setup
n.
004
Allocate the signal to CN1-4.
n.
005
Allocate the signal to CN1-5.
n.
006
Allocate the signal to CN1-6.
n.
007
Allocate the signal to CN1-7.
n.
008
Allocate the signal to CN1-8.
n.
009
Allocate the signal to CN1-9.
n.
010
Allocate the signal to CN1-10.
n.
011
Allocate the signal to CN1-11.
n.
012
Allocate the signal to CN1-12.
n.
013
Allocate the signal to CN1-13.
n.
014
Allocate the signal to CN1-14.
n.0
(default set-
ting)
Set the signal to always enable drive (always disable forc-
ing the motor to stop).
n.1
Enable drive when the input signal is ON (closed).
n.2
Enable drive when the input signal is OFF (open).
n.3
Set the signal to always prohibit drive (always force the
motor to stop).
Parameter
Description
When
Enabled
Classifi-
cation