1.2 Forcing the Motor to Stop
1.2.2 Setting the FSTP (Forced Stop Input) Signal
1-12
•
Σ
-7W SERVOPACKs with MECHATROLINK-III Communications References
For a
Σ
-7W SERVOPACK, you can set either Pn516 = n.
X or Pn597 = n.
XXX to allo-
cate the FSTP signal. To allocate the FSTP signals, always set either Pn516 = n.
X or
Pn597 = n.
XXX.
Parameter
Description
When
Enabled
Classifi-
cation
Pn516
n.
0
Axis A: Enable drive when CN1-3 input signal is ON
(closed).
Axis B: Enable drive when CN1-9 input signal is ON
(closed).
After
restart
Setup
n.
1
Axis A: Enable drive when CN1-4 input signal is ON
(closed).
Axis B: Enable drive when CN1-10 input signal is ON
(closed).
n.
2
Axis A: Enable drive when CN1-5 input signal is ON
(closed).
Axis B: Enable drive when CN1-11 input signal is ON
(closed).
n.
3
Axis A: Enable drive when CN1-6 input signal is ON
(closed).
Axis B: Enable drive when CN1-12 input signal is ON
(closed).
n.
4
Axis A: Enable drive when CN1-7 input signal is ON
(closed).
Axis B: Enable drive when CN1-13 input signal is ON
(closed).
n.
5
Axis A: Enable drive when CN1-8 input signal is ON
(closed).
Axis B: Enable drive when CN1-14 input signal is ON
(closed).
n.
6
Reserved setting (Do not use.)
n.
7
Set the signal to always prohibit drive (always force the
motor to stop).
n.
8
(default set-
ting)
Set the signal to always enable drive (always disable forc-
ing the motor to stop).
n.
9
Axis A: Enable drive when CN1-3 input signal is OFF
(open).
Axis B: Enable drive when CN1-9 input signal is OFF
(open).
n.
A
Axis A: Enable drive when CN1-4 input signal is OFF
(open).
Axis B: Enable drive when CN1-10 input signal is OFF
(open).
n.
B
Axis A: Enable drive when CN1-5 input signal is OFF
(open).
Axis B: Enable drive when CN1-11 input signal is OFF
(open).
n.
C
Axis A: Enable drive when CN1-6 input signal is OFF
(open).
Axis B: Enable drive when CN1-12 input signal is OFF
(open).
n.
D
Axis A: Enable drive when CN1-7 input signal is OFF
(open).
Axis B: Enable drive when CN1-13 input signal is OFF
(open).
n.
E
Axis A: Enable drive when CN1-8 input signal is OFF
(open).
Axis B: Enable drive when CN1-14 input signal is OFF
(open).
n.
F
Reserved setting (Do not use.)