3.1 Monitoring Product Life
3.1.3 Preventative Maintenance
3-4
•
Σ
-7S SERVOPACKs with MECHATROLINK-II Communications References or
Σ
-7S SERVO-
PACKs with MECHATROLINK-III Communications References
•
Σ
-7W SERVOPACKs with MECHATROLINK-III Communications References
Parameter
Description
When
Enabled
Classifi-
cation
Pn514
n.
0
(default setting)
Disabled (the above signal output is not used).
After
restart
Setup
n.
1
Output the signal from the CN1-1 or CN1-2 output ter-
minal.
n.
2
Output the signal from the CN1-23 or CN1-24 output
terminal.
n.
3
Output the signal from the CN1-25 or CN1-26 output
terminal.
Parameter
Description
When
Enabled
Classifi-
cation
Pn514
n.
0
(default setting)
Disabled (the above signal output is not used).
After
restart
Setup
n.
1
Axis A: Output the signal from the CN1-23 or CN1-24
output terminal.
Axis B: Output the signal from the CN1-25 or CN1-26
output terminal.
n.
2
Axis A: Output the signal from the CN1-27 or CN1-28
output terminal.
Axis B: Output the signal from the CN1-29 or CN1-30
output terminal.
Pn597
n.
023
Allocate the signal to CN1-23.
After
restart
Setup
n.
025
Allocate the signal to CN1-25.
n.
027
Allocate the signal to CN1-27.
n.
029
Allocate the signal to CN1-29.
n.
031
Allocate the signal to CN1-31.
n.0
(default setting)
Disabled (the above signal output is not used).
n.1
Output the above signal.
n.2
Invert the above signal and output it.