3.6 Setup Procedure
3.6.3 Setting and Checking Other Station Monitoring
3-12
When you connect multiple pressure sensors, set Pn9B4 to Pn9BF for other station monitor
channels 2 to 5 following the same procedure as for other station monitor channel 1.
Monitoring Methods
You can display the input values from pressure sensor amplifiers for two channels at the same
time. First, set other station monitoring with Pn824 or Pn825. Next, set the check channel with
Pn9C0.
*1.
You can check the other station monitor setting in the other station monitor value 1 (lower 16 bits) area of
Option Monitor 1 or 2 (32 bits).
Pn9B4
Other Station Monitor 2: Station Address
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0002 to FEEF
–
0002
After restart
Setup
Pn9B5
Other Station Monitor 2: Number of Transmission Bytes
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 4
–
3
After restart
Setup
Pn9B6
Other Station Monitor 2: Monitor Information Setting
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0000 to 14FF
–
1000
After restart
Setup
Pn9B7
Other Station Monitor 3: Station Address
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0002 to FEEF
–
0002
After restart
Setup
Pn9B8
Other Station Monitor 3: Number of Transmission Bytes
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 4
–
3
After restart
Setup
Pn9B9
Other Station Monitor 3: Monitor Information Setting
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0000 to 14FF
–
1000
After restart
Setup
Pn9BA
Other Station Monitor 4: Station Address
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0002 to FEEF
–
0002
After restart
Setup
Pn9BB
Other Station Monitor 4: Number of Transmission Bytes
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 4
–
3
After restart
Setup
Pn9BC
Other Station Monitor 4: Monitor Information Setting
Setting Range
Setting Unit
Default Setting
When Enabled
分類
0000 to 14FF
–
1000
After restart
Setup
Pn9BD
Other Station Monitor 5: Station Address
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0002 to FEEF
–
0002
After restart
Setup
Pn9BE
Other Station Monitor 5: Number of Transmission Bytes
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0 to 4
–
3
After restart
Setup
Pn9BF
Other Station Monitor 5: Monitor Information Setting
Setting Range
Setting Unit
Default Setting
When Enabled
Classification
0000 to 14FF
–
1000
After restart
Setup
Parameter
Meaning
When Enabled
Classification
Pn824
0101h
You can check other station monitor data with
Option Monitor 1.
Immediately
Setup
Pn825
0101h
You can check other station monitor data with
Option Monitor 2.
Parameter
Meaning
When Enabled
Classification
Pn9C0
n.
X
*1
Set the other station monitor number (1 to 5).
After restart
Setup
n.
X
*2
Set the other station monitor number (1 to 5).
Torque
Torque
Torque
Torque
Torque
Torque
Torque
Torque
Torque
Torque
Torque
Torque