6.2 FT40 Specification
6.2.3 Parameter Recording Table
6-68
45
PnA8A
0h
Acceleration Unit Selection
After restart
46
PnA8C
4
Acceleration Base Unit
Selection
After restart
47
PnA8E
1h
Torque Unit Selection
After restart
48
PnA90
0
Torque Base Unit Selection
After restart
49
PnA92
0601011Fh
Supported Unit Systems
(read only)
–
61
PnAC2
40000
Speed Loop Gain
Immediately
62
PnAC4
20000
Speed Loop Integral Time
Constant
Immediately
63
PnAC6
40000
Position Loop Gain
Immediately
64
PnAC8
0
Feedforward Compensation Immediately
65
PnACA
0
Position Loop Integral Time
Constant
Immediately
66
PnACC
7
Positioning Completed
Width
Immediately
67
PnACE
1073741824
Near Signal Width
Immediately
81
PnB02
0
Exponential Acceleration/
Deceleration Time Constant
Immedi-
ately
*3
82
PnB04
0
Movement Average Time
Immedi-
ately
*3
83
PnB06
100
External Positioning Final
Travel Distance
Immediately
84
PnB08
×
5,000h reference
units/s converted to
10
-3
min
-1
Origin Approach Speed
Immediately
85
PnB0A
×
500h reference
units/s converted to
10
-3
min
-1
Origin Return Creep Speed
Immediately
86
PnB0C
100
Final Travel Distance for
Origin Return
Immediately
87
PnB0E
1
h
Fixed Monitor Selection 1
Immediately
88
PnB10
0
h
Fixed Monitor Selection 2
Immediately
89
PnB12
0
h
SEL_MON (CMN1) Monitor
Selection 1
Immediately
8A
PnB14
0
h
SEL_MON (CMN2) Monitor
Selection 2
Immediately
8B
PnB16
10
Origin Detection Width
Immediately
8C
PnB18
100
Forward Torque Limit
Immediately
8D
PnB1A
100
Reverse Torque Limit
Immediately
8E
PnB1C
20000
Zero Speed Detection
Range
Immediately
Continued on next page.
Continued from previous page.
Parameter
No.
Default Setting
Name
When
Enabled
Summary of Contents for SERVOPACK Sigma 7 Series