6.2 FT40 Specification
6.2.1 List of Servo Parameters
6-15
6
Parameter Lists
Pn144
2
Model Following Con-
trol Bias in the Reverse
Direction
0 to 10,000
0.1%
1000
All
Immedi-
ately
Tuning
*1
Pn145
2
Vibration Suppression 1
Frequency A
10 to 2,500
0.1 Hz
500
All
Immedi-
ately
Tuning
*1
Pn146
2
Vibration Suppression 1
Frequency B
10 to 2,500
0.1 Hz
700
All
Immedi-
ately
Tuning
*1
Pn147
2
Model Following Con-
trol Speed Feedforward
Compensation
0 to 10,000
0.1%
1000
All
Immedi-
ately
Tuning
*1
Pn148
2
Second Model Follow-
ing Control Gain
10 to 20,000
0.1/s
500
All
Immedi-
ately
Tuning
*1
Pn149
2
Second Model Follow-
ing Control Gain Correc-
tion
500 to 2,000
0.1%
1000
All
Immedi-
ately
Tuning
*1
Pn14A
2
Vibration Suppression 2
Frequency
10 to 2,000
0.1 Hz
800
All
Immedi-
ately
Tuning
*1
Pn14B
2
Vibration Suppression 2
Correction
10 to 1,000
1%
100
All
Immedi-
ately
Tuning
*1
Pn14F
2
Control-Related Selec-
tions
0000h to
0021h
–
0021h
All
After
restart
Tuning
*1
Pn160
2
Anti-Resonance Con-
trol-Related Selections
0000h to
0011h
–
0010h
All
Immedi-
ately
Tuning
*1
Pn161
2
Anti-Resonance Fre-
quency
10 to 20,000
0.1 Hz
1000
All
Immedi-
ately
Tuning
*1
Pn162
2
Anti-Resonance Gain
Correction
1 to 1,000
1%
100
All
Immedi-
ately
Tuning
*1
Pn163
2
Anti-Resonance Damp-
ing Gain
0 to 300
1%
0
All
Immedi-
ately
Tuning
*1
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Model Following Control Type Selection
0
Use model following control type 1.
1
Use model following control type 2.
n.
X
Tuning-less Type Selection
0
Use tuning-less type 1.
1
Use tuning-less type 2.
2
Use tuning-less type 3.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.
X
Anti-Resonance Control Selection
0
Do not use anti-resonance control.
1
Use anti-resonance control.
n.
X
Anti-Resonance Control Adjustment Selection
0
Do not adjust anti-resonance control automatically during execution of auto-
tuning without a host reference, autotuning with a host reference, and custom
tuning.
1
Adjust anti-resonance control automatically during execution of autotuning
without a host reference, autotuning with a host reference, and custom tun-
ing.
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
Summary of Contents for SERVOPACK Sigma 7 Series