5.2 FT41 Specification
5.2.5 List of Warnings
5-96
A.920
Regenerative Overload
This warning occurs before an A.320 alarm (Regenera-
tive Overload) occurs. If the warning is ignored and
operation is continued, an alarm may occur.
Required.
A.921
Dynamic Brake Over-
load
This warning occurs before an A.731 alarm (Dynamic
Brake Overload) occurs. If the warning is ignored and
operation is continued, an alarm may occur.
Required.
A.922
Pressure Feedback
Overflow
The pressure feedback detection value exceeded the
level set in Pn44D (Pressure Feedback Overflow Detec-
tion Level) for the time set in Pn44E (Pressure Feedback
Overflow Detection Time).
Required.
A.923
SERVOPACK Built-in
Fan Stopped
The fan inside the SERVOPACK stopped.
Required.
A.930
Absolute Encoder Bat-
tery Error
This warning occurs when the voltage of absolute
encoder’s battery is low.
Required.
A.942
Speed Ripple Com-
pensation Information
Disagreement
The speed ripple compensation information stored in
the encoder does not agree with the speed ripple com-
pensation information stored in the SERVOPACK.
Required.
A.94A
Data Setting Warning 1
(Parameter Number
Error)
There is an error in the parameter number for a Data
Setting Warning 1 (Parameter Number) command.
Automatically
reset.
*
A.94b
Data Setting Warning 2
(Out of Range)
The command data is out of range.
Automatically
reset.
*
A.94C
Data Setting Warning 3
(Calculation Error)
A calculation error was detected.
Automatically
reset.
*
A.94d
Data Setting Warning 4
(Parameter Size)
The data sizes do not match.
Automatically
reset.
*
A.94E
Data Setting Warning 5
(Latch Mode Error)
A latch mode error was detected.
Required.
A.95A
Command Warning 1
(Unsatisfied Com-
mand Conditions)
A command was sent when the conditions for sending
a command were not satisfied.
Automatically
reset.
*
A.95b
Command Warning 2
(Unsupported Com-
mand)
An unsupported command was sent.
Automatically
reset.
*
A.95d
Command Warning 4
(Command Interfer-
ence)
There was command interference, particularly latch
command interference.
Automatically
reset.
*
A.95E
Command Warning 5
(Subcommand Not
Possible)
The subcommand and main command interfere with
each other.
Automatically
reset.
*
A.95F
Command Warning 6
(Undefined Command)
An undefined command was sent.
Automatically
reset.
*
A.960
MECHATROLINK
Communications
Warning
A communications error occurred during MECHA-
TROLINK communications.
Required.
A.964
Other Station Monitor
Data Communications
Warning
A communications error occurred during MECHA-
TROLINK communications.
Required.
A.971
Undervoltage
This warning occurs before an A.410 alarm (Undervolt-
age) occurs. If the warning is ignored and operation is
continued, an alarm may occur.
Required.
A.97A
Command Warning 7
(Phase Error)
A command that cannot be executed in the current
phase was sent.
Automatically
reset.
*
A.97b
Data Clamp Out of
Range
The set command data was clamped to the minimum or
maximum value of the allowable setting range.
Automatically
reset.
*
A.9A0
Overtravel
Overtravel was detected while the servo was ON.
Required.
Continued on next page.
Continued from previous page.
Warning
Number
Warning Name
Meaning
Resetting
Summary of Contents for SERVOPACK Sigma 7 Series