2.1 Ratings
2-4
*
This is the net value at the rated load.
Single-Phase, 100 VAC
*
This is the net value at the rated load.
Model SGD7S-
180A
200A
330A
470A
550A
590A
780A
Maximum Applicable Motor Capacity [kW]
2.0 3.0 5.0 6.0 7.5 11.0
15.0
Continuous Output Current [Arms]
18.5
19.6
32.9
46.9
54.7
58.6
78.0
Instantaneous Maximum Output Current [Arms]
42.0 56.0 84.0 110 130 140 170
Main Circuit
Power Supply
270 VDC to 324 VDC, -15% to +10%
Input Current [Arms]
*
14
20
34
36
48
68
92
Control
Power Supply
270 VDC to 324 VDC, -15% to +10%
Input Current [Arms]
*
0.25
0.25
0.3
0.3
0.3
0.4
0.4
Power Supply Capacity [kVA]
*
4.0 5.9 7.5 10.7 14.6 21.7 29.6
Power Loss
*
Main Circuit Power
Loss [W]
82.7
83.5
146.2
211.6
255.3
243.6
343.4
Control Circuit Power
Loss [W]
16
16
19
21
21
28
28
Total Power Loss [W]
98.7
99.5
165.2
232.6
276.3
271.6
371.4
Overvoltage Category
III
Model SGD7S-
R70F
R90F
2R1F
2R8F
Maximum Applicable Motor Capacity [kW]
0.05
0.1
0.2
0.4
Continuous Output Current [Arms]
0.66
0.91
2.1
2.8
Instantaneous Maximum Output Current [Arms]
2.1 3.2 6.5 9.3
Main Circuit
Power Supply
100 VAC to 120 VAC, -15% to +10%, 50 Hz/60 Hz
Input Current [Arms]
*
1.5
2.5
5
10
Control
Power Supply
100 VAC to 120 VAC, -15% to +10%, 50 Hz/60 Hz
Input Current [Arms]
*
0.38
0.38
0.38
0.38
Power Supply Capacity [kVA]
*
0.2
0.3
0.6
1.4
Power Loss
*
Main Circuit Power
Loss [W]
5.3
7.8
14.2
26.2
Control Circuit Power
Loss [W]
12
12
12
12
Total Power Loss [W]
17.3
19.8
26.2
38.2
Regenerative Resistor
Minimum Allowable
Resistance [
Ω
]
40
40
40
40
Overvoltage Category
III