5
Alarm and Error
5.1 Alarm
5-10
169861-1CD
HW1482771
Weldcom Function: Arc
Welding Digital I/F
4290
TPS:
ERROR
78
E-Stop
Sub code[78**] shows the error code of
Fronius power source
78 :main error code
** :sub error code
Close the Safety circuit and activate
the Error reset
Confirm the Fronius's manual
79
ErrU0
Sub code[79**] shows the error code of
Fronius power source
79 :main error code
** :sub error code
Confirm the Fronius's manual
80
Err080
Sub code[80**] shows the error code of
Fronius power source
80 :main error code
** :sub error code
Check the connection hose pack
between power source and wire
feeder
Confirm the Fronius's manual
81
tP7hot
Sub code[81**] shows the error code of
Fronius power source
81 :main error code
** :sub error code
Allow the machine to cool
Confirm the Fronius's manual
82
ErrEHF
Sub code[82**] shows the error code of
Fronius power source
82 :main error code
** :sub error code
Allow the external HF to cool down
Confirm the Fronius's manual
83
PHASE
Sub code[83**] shows the error code of
Fronius power source
83 :main error code
** :sub error code
Check the mains supply cable of the
power source
Confirm the Fronius's manual
84
unknown
Sub code[84**] shows the error code of
Fronius power source
84 :main error code
** :sub error code
OR NOT IN USE
Confirm the Fronius's manual
85
unknown
Sub code[85**] shows the error code of
Fronius power source
85 :main error code
** :sub error code
OR NOT IN USE
Confirm the Fronius's manual
86
unknown
Sub code[86**] shows the error code of
Fronius power source
86 :main error code
** :sub error code
OR NOT IN USE
Confirm the Fronius's manual
Alarm
No.
Alarm
Name
Sub
Code
Meaning
Remedy
60 of 75