3-11
169861-1CD
HW1482771
3
Operation of Welding Condition File Edit Window
3.10 FroniusTPS Type: Operation of Param. setting Window
Weldcom Function: Arc
Welding Digital I/F
3.10
FroniusTPS Type: Operation of Param. setting Window
1. At the top window, select {Param. setting}.
– Change the parameter of the weld user file selected.
2. Select {Gas/Wire}.
(1) Gas preflow: Pre-flow that the robot performs as approaching the
welding start point.
(2) Gas postflow: Specify the time period of gas release performed at
the end of the welding.
(3) SFI: Select from “AUTO”, “MANUAL”, or “OFF”. Feeding rate
when the wire is approaching the
base material at the touch start.
3. Select {Synchropulse}.
– Change the welding parameters for changing the feeding rate or arc
length in low-cycle pulses at the time of welding. For details, see the
user manual of the welding power source.
4. Select {SAVE}.
– Apply the parameters changed.
43 of 75