5-3
169861-1CD
HW1482771
5
Alarm and Error
5.1 Alarm
Weldcom Function: Arc
Welding Digital I/F
4290
TPS:
ERROR
18
ErrbPS
Sub code[18**] shows the error code of
Fronius power source
18 :main error code
** :sub error code
Update firmware, otherwise change
the UST board or otherwise change
the BPS board
Confirm the Fronius's manual
19
Err IP
Sub code[19**] shows the error code of
Fronius power source
19 :main error code
** :sub error code
Change the BPS board
Change the secondary diode
Change the welding transformer
Confirm the Fronius's manual
20
DSPAxx
Sub code[20**] shows the error code of
Fronius power source
20 :main error code
** :sub error code
Update firmware, otherwise change
the UST board
Confirm the Fronius's manual
21
DSPExx
Sub code[21**] shows the error code of
Fronius power source
21 :main error code
** :sub error code
Update firmware, otherwise change
the UST board
Confirm the Fronius's manual
22
ErrEPF
Sub code[22**] shows the error code of
Fronius power source
22 :main error code
** :sub error code
Update firmware, otherwise change
the UST board
Confirm the Fronius's manual
23
Err23.x
Sub code[23**] shows the error code of
Fronius power source
23 :main error code
** :sub error code
Update firmware, otherwise change
the UST board
Confirm the Fronius's manual
24
Err24.x
Sub code[24**] shows the error code of
Fronius power source
24 :main error code
** :sub error code
Update firmware, otherwise change
the UST board
Confirm the Fronius's manual
25
Err25.x
Sub code[25**] shows the error code of
Fronius power source
25 :main error code
** :sub error code
Update firmware, otherwise change
the UST board
Confirm the Fronius's manual
Alarm
No.
Alarm
Name
Sub
Code
Meaning
Remedy
53 of 75