5-7
169861-1CD
HW1482771
5
Alarm and Error
5.1 Alarm
Weldcom Function: Arc
Welding Digital I/F
4290
TPS:
ERROR
52
Err052
Sub code[52**] shows the error code of
Fronius power source
52 :main error code
** :sub error code
Mains voltage too high or NT 24
defective
Confirm the Fronius's manual
53
ErrPE
Sub code[53**] shows the error code of
Fronius power source
53 :main error code
** :sub error code
Low-resistance connection between
secondary and machine housing find
out the cause
Confirm the Fronius's manual
54
Err054
Sub code[54**] shows the error code of
Fronius power source
54 :main error code
** :sub error code
Increase the bbc (burn-back control)
Switch off “Wire stick” in the set-up
menu
After the end of welding, make sure
that the wire does not collide with the
workpiece when the torch is
retracted.
Confirm the Fronius's manual
55
NoIGn
Sub code[55**] shows the error code of
Fronius power source
55 :main error code
** :sub error code
Set a lower Ito value
Keep the torch stand-off distance
smaller before ignition.
Confirm the Fronius's manual
56
Err056
Sub code[56**] shows the error code of
Fronius power source
56 :main error code
** :sub error code
Check how much wire is left on the
spool
If necessary, change the spool
Confirm the Fronius's manual
57
NoGAS
Sub code[57**] shows the error code of
Fronius power source
57 :main error code
** :sub error code
Check what volume of gas is still
available
Confirm the Fronius's manual
58
NoArc
Sub code[58**] shows the error code of
Fronius power source
58 :main error code
** :sub error code
Check the seam
Confirm the Fronius's manual
59
Err059
Sub code[59**] shows the error code of
Fronius power source
59 :main error code
** :sub error code
Confirm the Fronius's manual
Alarm
No.
Alarm
Name
Sub
Code
Meaning
Remedy
57 of 75