Setup
2.5 System Configuration
2-16
169861-1CD
HW1482771
Weldcom Function: Arc
Welding Digital I/F
Unit:10 ms
Range: 5 (50 ms) - 30 (300 ms)
If it is out of range, 100 ms will be set (initial setting).
2.5.10 Optional Parameter for FroniusTPSi
It can change the switching rule for TPSi working mode
0: Switch to the mode selected by welding condition (Initial setting)
1: Switch the mode with following rule.
Executing a job
→
Switch to the mode selected by welding condition
NOT Executing a job
→
“INTERNAL” mode (fixed)
Unit: 10 ms
Range: 5 (50 ms) - 30 (300 ms)
If it is out of range, 100 ms will be set (initial setting).
Parameter
Name
-RS380
Timeout lifecycle of welder
Parameter
Name
-AxP107
Designation of switching TPSi working mode
Parameter
Name
-RS380
Timeout lifecycle of welder
32 of 75