10.20 Parameters Changed by E1-03 [V/f Pattern Selection]
622
YASKAWA ELECTRIC
SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
*2
The default setting varies depending on the setting of
E5-01 [Motor Code Selection]
.
*3
This is the value for 200 V class drives. Double the value for 400 V class drives.
Table 10.3 Parameters Changed by E1-03 (2257 to 2415 and 4140 to 4675)
No.
Uni
t
Setting
Control Method (Value
set in A1-02)
E1-
03
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
OL
V
(2)
CLV
(3)
OL
V/
PM
(5)
AO
LV/
PM
(6)
CL
V/
PM
(7)
E1-
04
Hz
50.0 60.0 60.0 72.0 50.0 50.0 60.0 60.0 50.0 50.0 60.0 60.0 90.0
120.
0
180.
0
50.0
50.0 50.0
E1-
05
V
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
200.
0
E1-
06
Hz
50.0 60.0 50.0 60.0 50.0 50.0 60.0 60.0 50.0 50.0 60.0 60.0 60.0 60.0 60.0
50.0
50.0 50.0
E1-
07
Hz
2.5
3.0
3.0
3.0
25.0 25.0 30.0 30.0
2.5
2.5
3.0
3.0
3.0
3.0
3.0
2.5
3.0
0.0
-
-
-
E1-
08
V
12.0 12.0 12.0 12.0 35.0 50.0 35.0 50.0 15.0 20.0 15.0 20.0 12.0 12.0 12.0
12.0
13.2
0.0
-
-
-
E1-
09
Hz
1.3
1.5
1.5
1.5
1.3
1.3
1.5
1.5
1.3
1.3
1.5
1.5
1.5
1.5
1.5
1.3
0.5
0.0
0.0
E1-
10
V
6.0
6.0
6.0
6.0
5.0
6.0
5.0
6.0
7.0
9.0
7.0
11.0
6.0
6.0
6.0
6.0
2.4
0.0
-
-
-
*1
These values are the default settings for
E1-04 through E1-10
and
E3-04 through E3-10 [V/f Pattern for Motor 2]
. These settings are
the same as those for the V/f pattern when
E1-03 = 1 [Constant Trq_60Hz base_60Hz max]
.
*2
The default setting varies depending on the setting of
E5-01 [Motor Code Selection]
.
*3
This is the value for 200 V class drives. Double the value for 400 V class drives.